{"product_id":"fluke-fi-7000","title":"Fluke Networks FI-7000 FiberInspector™ Pro - FI2-7000 INT","description":"1-second automated PASS\/FAIL certification of fibre optic connector end-faces with the Fluke Networks FI-7000.\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated Pass\/Fail certification of fibre optic connector end-faces\u003c\/li\u003e\n\u003cli\u003eGraphical indication of problem areas due to contamination, pits, chips, and scratches\u003c\/li\u003e\n\u003cli\u003eCertify to industry standards - IEC 61300-3-35\u003c\/li\u003e\n\u003cli\u003eEliminate human subjectivity from fibre optic connector end-face measurements\u003c\/li\u003e\n\u003cli\u003eSave fibre optic connector end-face views during certification process\u003c\/li\u003e\n\u003cli\u003eVersiv™ modular design supports copper certification, fibre optic loss, OTDR testing and fibre end-face inspection\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePerfect for fibre inspection\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003eFibre optic connector end-face contamination is a leading cause of fibre failures. Dirt and contaminant cause insertion loss and back-reflection that inhibits optical transmission and causes havoc with transceivers. Fibre loss and OTDR testing can expose this problem, but in many cases, dirty connections make fibre testing time consuming and inaccurate.\u003c\/p\u003e\n\u003cp\u003eSince dirt can be an issue before, during, or after fibre optic certification testing, and migrate from one fibre optic connector end-face to another upon mating, both sides of any connection must always be cleaned and inspected. Further, mating contaminated fibre optic connectors can cause permanent damage as microscopic debris is crushed between end-faces in physical contact. Even factory terminated patch cords or pigtails must be inspected as protective caps do not keep fibre optic connector end-faces clean. Avoiding this common cause of failure, starts with inspecting the fibre optic connector end-face and eliminating any contamination before insertion into a bulkhead or piece of equipment.\u003c\/p\u003e\n\u003cp\u003eThe FI-7000 FiberInspector Pro is a fibre optic inspection scope that allows you to inspect and certify fibre optic connector end-faces in 1 seconds so you can get the job done the first time. This fibre optic inspection scope provides automated PASS\/FAIL certification take the guess work out of fibre inspection so anyone can be a fibre expert.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFiber Inspection Certification\u003c\/li\u003e\n\u003cli\u003eGraphical indication of Problem Areas\u003c\/li\u003e\n\u003cli\u003eStore End-face Images\u003c\/li\u003e\n\u003cli\u003eBuilt on the Versiv Platform\u003c\/li\u003e\n\u003cli\u003eVersiv’s ProjX™ System\u003c\/li\u003e\n\u003cli\u003eTaptive™ User Interface\u003c\/li\u003e\n\u003cli\u003eLinkWare™ Live Test Results Management Service\u003c\/li\u003e\n\u003cli\u003eLinkWare™ Management Software\u003c\/li\u003e\n\u003cli\u003ePASS\/FAIL Fiber End-face Grading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"product-feature-title ui-accordion-header ui-helper-reset ui-state-default ui-corner-all ui-accordion-icons\" role=\"tab\" id=\"ui-accordion-1-header-1\" aria-controls=\"ui-accordion-1-panel-1\" aria-selected=\"false\" tabindex=\"-1\"\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable0\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInspection Probe specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2M pixels\u003c\/td\u003e\n\u003ctd\u003eBlue LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eBlue LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower source\u003c\/td\u003e\n\u003ctd\u003eVersiv mainframe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eField of View (FOV)\u003c\/td\u003e\n\u003ctd\u003eHorizontal: 425 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVertical: 320 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum detectable particle size\u003c\/td\u003e\n\u003ctd\u003e0.5 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 6.75 in x 1.5 in (1175 mm x 35 mm) without adapter tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003eOperating: 32°F to 122°F (0 °C to +50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage: -4°F to +158°F (-20°C to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eMainframe with module and battery: 3 lbs, 5 oz (1.28 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eMainframe with module and battery: 2.625 in x 5.25 in x 11.0 in ( 6.67 cm x 13.33 cm x 27.94 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eLithium ion battery pack, 7.2 volts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003eEleven hour with Inspection probe attached\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharge Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTester Off\u003c\/td\u003e\n\u003ctd\u003eFour hours to charge from 10% to 90% capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTester On\u003c\/td\u003e\n\u003ctd\u003eSix hours to charge from 10% to 90% capacity with the tester on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature*\u003c\/td\u003e\n\u003ctd\u003e-18ºC to 45ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating temperature\u003c\/td\u003e\n\u003ctd\u003e-30ºC to 60ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e4,000 m (13123 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3200 m (10,500 ft) with ac adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e* Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":2526922407968,"sku":"FI2-7000 INT","price":4472.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/FI-7000_FiberInspector_Pro.jpg?v=1567584736","url":"https:\/\/networx-direct.myshopify.com\/products\/fluke-fi-7000","provider":"networktesters.co.uk","version":"1.0","type":"link"}