{"product_id":"fluke-dsx-602-intl","title":"Fluke Networks DSX-602 CableAnalyzer™ - DSX-602 INT","description":"\u003cp\u003e\u003cspan\u003eThe DSX-602 CableAnalyzer™ is the tool for essential certification of copper, twisted pair structured cabling from Cat 3 \/ Class C through Cat 6A \/ Class E\u003c\/span\u003e\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e features speed, and reliability that makes you more efficient and productive – you can see the results on the bottom line. No other tester will deliver as consistently as the DSX-600. Its gesture-based user interface allows your techs to spend less time interpreting screens and more time testing. 500 MHz frequency range certifies Cat 6A\/Class E\u003c\/span\u003e\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e cabling for 10 Gigabit Ethernet in just 10 seconds. Advanced diagnostics pinpoint the location of a failure. LinkWare™ Live cloud-based service that lets you manage certification jobs anytime, anywhere, with anyone on any device.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eCat 6A and Class E\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eCopper Certification\u003c\/li\u003e\n\u003cli\u003eIncludes Channel Measurement Adapters; Optional rugged Permanent Link Adapters with removable test plug available\u003c\/li\u003e\n\u003cli\u003e10 second Cat 6A test time\u003c\/li\u003e\n\u003cli\u003eProjX™ Management System makes test setup fast and foolproof\u003c\/li\u003e\n\u003cli\u003eHDTDX and HDTDR diagnostics pinpoint fault location\u003c\/li\u003e\n\u003cli\u003eIntegrates with LinkWare™ Live to manage jobs and testers from any smart device.\u003c\/li\u003e\n\u003cli\u003eQuickly and easily create professional custom PDF reports with LinkWare™ PC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #0000ff;\"\u003eGot any questions about the DSX-602 CableAnalyzer™ ? You can speak to one of our team during office hours. Just call 01403 756588\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe DSX-602 enables users to accomplish more than ever before by accelerating every step of the testing process\u003c\/li\u003e\n\u003cli\u003eLinkWare Live cloud service lets the Project Manager remotely set up the testers, monitor job progress and even location from any smart device\u003c\/li\u003e\n\u003cli\u003eProjX™ management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time\u003c\/li\u003e\n\u003cli\u003eTaptive™ user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels\u003c\/li\u003e\n\u003cli\u003eLinkWare PC management software provides unmatched analysis of test results and professional test reports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable0\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCable Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielded and unshielded pair LAN cabling\u003c\/td\u003e\n\u003ctd\u003eTIA Category 3, 4, 5, 5e, 6, 6A: 100 Ω\u003cbr\u003eISO\/IEC Class C, D, E, E\u003csub\u003eA\u003c\/sub\u003e: 100 Ω and 120 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable0\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTest Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTIA\u003c\/td\u003e\n\u003ctd\u003eCategory 3, 5, 5e, 6, 6A per TIA 568-C.2 or TIA-1005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISO\/IEC\u003c\/td\u003e\n\u003ctd\u003eClass C and D, E, E\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ecertification per ISO\/IEC 11801:2002 and amendments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum frequency\u003c\/td\u003e\n\u003ctd\u003eDSX-600: 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eStandard Link Interface Adapters\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermanent link adapters\u003c\/td\u003e\n\u003ctd\u003ePlug type: shielded RJ45 (for DSX-600-PRO only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable3\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed of Autotest\u003c\/td\u003e\n\u003ctd\u003eFull 2-way Autotest of Category 5e or 6\/Class D or E: 9 seconds;\u003cbr\u003eFull 2-way Autotest of Category 6A\/Class E\u003csub\u003eA\u003c\/sub\u003e: 10 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported test parameters (test standard determines parameters and frequency range reported)\u003c\/td\u003e\n\u003ctd\u003eWire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), Near End Crosstalk (NEXT), Attenuation-to-Crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (PS ELFEXT), Power Sum NEXT, Power Sum ACR-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum frequency\u003c\/td\u003e\n\u003ctd\u003e500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Result Storage\u003c\/td\u003e\n\u003ctd\u003e12,000 Cat 6A with plots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5.7 in LCD display with a projected capacitance touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eMain Unit and Smart Remote: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3 lbs (1.36 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eLithium ion battery pack, 7.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Charge Time\u003c\/td\u003e\n\u003ctd\u003e4 hours (below 40° C, with tester off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable4\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e32° F to 113° F (0° C to 45° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-22° F to +140° F (-30° C to +60° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (% RH without condensation)\u003c\/td\u003e\n\u003ctd\u003e0% to 90%, 32° F to 95° F: (0° C to 35° C)\u003cbr\u003e0% to 70%, 95° F to 113° F: (35° C to 45° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eRandom, 2 g, 5 Hz -500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e1 m drop test with and without module and adapter attached\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eCSA 22.2 No. 61010, IEC 61010-1 3\u003csup\u003erd\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eEdition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e13,123 ft (4,000 m)\u003cbr\u003e10,500 ft (3,200 m) with ac adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 61326-1: Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":2526680612896,"sku":"DSX-602 INT","price":8014.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/17103_Fn-dsx-600-EN-ENGLISH_01a_cMAIN.jpg?v=1575379135","url":"https:\/\/networx-direct.myshopify.com\/products\/fluke-dsx-602-intl","provider":"networktesters.co.uk","version":"1.0","type":"link"}