{"product_id":"dsx2-add-r","title":"Fluke Networks DSX2-5000 CableAnalyzer Module Add On Kit With V2 Remote - DSX2-ADD-R","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFluke Networks DSX-5000 Add on Kit : VERSION 2 WITH BUILT IN WIFI\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke Networks DSX 5000 add on kit, with remote, (DSX-ADD-R) is for use with the Versiv 2 mainframe but need DSX-5000 CableAnalyzer Modules for Copper Certification and a Versiv Remote. NOTE: This add on kit does not include the Versiv mainframe.\u003c\/p\u003e\n\u003cp\u003eSee Specifications and Part Numbers sections for full product details.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProjX™ Management System Manages Complex Jobs with Ease\u003c\/li\u003e\n\u003cli\u003eTaptive™ User Interface Simplifies Set Up, Eliminates Errors and Speeds Troubleshooting\u003c\/li\u003e\n\u003cli\u003ePerforms with Unsurpassed Speed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable0\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCable Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielded and unshielded pair LAN cabling\u003c\/td\u003e\n\u003ctd\u003eTIA Category 3, 4, 5, 5e, 6, 6A, 8: 100 Ω\u003cbr\u003eISO\/IEC Class C, D, E, E\u003csub\u003eA\u003c\/sub\u003e, F, F\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand I\/II: 100 Ω and 120 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable1\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eStandard Link Interface Adapters\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermanent link adapters\u003c\/td\u003e\n\u003ctd\u003ePlug type: shielded RJ45\u003cbr\u003eOptional Plug type: Tera (for DSX-5000 only, DSX-8000 version available summer 2017)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Adapters\u003c\/td\u003e\n\u003ctd\u003eJack type: shielded RJ45\u003cbr\u003eOptional Jack type: Tera (for DSX-5000 only, DSX-8000 version available summer 2017)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable2\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTest Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTIA\u003c\/td\u003e\n\u003ctd\u003eCategory 3, 4, 5, 5e, 6, 6A, 8 per TIA 568-C.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISO\/IEC\u003c\/td\u003e\n\u003ctd\u003eClass C and D, E, E\u003csub\u003eA\u003c\/sub\u003e, F, F\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand I\/II certification per ISO\/IEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum frequency\u003c\/td\u003e\n\u003ctd\u003eDSX-8000: 2000 MHz;\u003cbr\u003eDSX-5000: 1000 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable3\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSpeed of Autotest\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eDSX-5000:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFull 2-way Autotest of Category 5e or 6\/Class D or E:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9 seconds\u003c\/strong\u003e. Full 2-way Autotest of Category 6A\/Class E\u003csub\u003eA\u003c\/sub\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10 seconds\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported test parameters (The selected test standard determines the test parameters and the frequency range of the tests)\u003c\/td\u003e\n\u003ctd\u003eWire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput protection\u003c\/td\u003e\n\u003ctd\u003eProtected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5.7 in LCD display with a projected capacitance touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase\u003c\/td\u003e\n\u003ctd\u003eHigh impact plastic with shock absorbing overmold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eMain Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eMain Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain unit and remote:\u003c\/td\u003e\n\u003ctd\u003eLithium ion battery pack, 7.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical battery life:\u003c\/td\u003e\n\u003ctd\u003e8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge time*\u003c\/td\u003e\n\u003ctd\u003eTester off: 4 hours to charge from 10 % capacity to 90 % capacity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages supported\u003c\/td\u003e\n\u003ctd\u003eEnglish, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eService center calibration period is 1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable4\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e32°F to 113°F (0°C to 45°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-14°F to +140°F (-10°C to +60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity\u003c\/td\u003e\n\u003ctd\u003e0 % to 90 %, 32°F to 95 °F (0°C to 35°C)\u003cbr\u003e0 % to 70 %, 95°F to 113 °F (35°C to 45°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eRandom, 2 g, 5 Hz-500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e1 m drop test with and without module and adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eCSA 22.2 No. 61010, IEC 61010-1 3\u003csup\u003erd\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eEdition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e13,123 ft (4,000 m)\u003cbr\u003e10,500 ft (3,200 m) with ac adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable5\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003ePerformance Specifications **\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDSX-5000\u003c\/td\u003e\n\u003ctd\u003eCategory 6A\/Class E\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003etest modes (or lower link categories)\u003c\/td\u003e\n\u003ctd\u003eExceed Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass F\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003etest modes\u003c\/td\u003e\n\u003ctd\u003eExceed Level V requirements as in the draft 4th edition of IEC 61935-1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable6\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLength of Twisted Pair Cabling\u003csup\u003e1\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWithout Remote\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWith Remote\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e800 m (2600 ft)\u003c\/td\u003e\n\u003ctd\u003e150 m (490 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 m or 1 ft\u003c\/td\u003e\n\u003ctd\u003e0.1 m or 1 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e± (0.3 m + 2 %); 0 m to 150 m\u003cbr\u003e± (0.3 m + 4 %); 150 m to 800 m\u003c\/td\u003e\n\u003ctd\u003e± (0.3 m + 2 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable7\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003ePropagation Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWithout Remote\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWith Remote\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e4000 ns\u003c\/td\u003e\n\u003ctd\u003e750 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 ns\u003c\/td\u003e\n\u003ctd\u003e1 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e± (2 ns + 2 %); 0 ns to 750 ns\u003cbr\u003e± (2 ns + 4 %); 750 ns to 4000 ns\u003c\/td\u003e\n\u003ctd\u003e± (2 ns + 2 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable8\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDelay Skew\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 ns to 100 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e± 10 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable9\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC Loop Resistance Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 Ω to 540 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e± (1 Ω + 1 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload recovery time\u003c\/td\u003e\n\u003ctd\u003eLess than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":8636565684329,"sku":"DSX2-ADD-R","price":12557.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/Fn-dsx-add-r_01f_ko.png?v=1569067210","url":"https:\/\/networx-direct.myshopify.com\/products\/dsx2-add-r","provider":"networktesters.co.uk","version":"1.0","type":"link"}