{"title":"Fibre Testers","description":"\u003cp\u003eFibre testers from Fluke Networks\u003c\/p\u003e\n\u003cp\u003eIs your fibre cable working correctly? Check continuity with a VFL. Accurately measure loss using light source and power meter kits. Fault find breaks or bad connections in your fibre links with easy to use Fluke Networks fibre testers.\u003c\/p\u003e","products":[{"product_id":"fluke-fi-7000","title":"Fluke Networks FI-7000 FiberInspector™ Pro - FI2-7000 INT","description":"1-second automated PASS\/FAIL certification of fibre optic connector end-faces with the Fluke Networks FI-7000.\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated Pass\/Fail certification of fibre optic connector end-faces\u003c\/li\u003e\n\u003cli\u003eGraphical indication of problem areas due to contamination, pits, chips, and scratches\u003c\/li\u003e\n\u003cli\u003eCertify to industry standards - IEC 61300-3-35\u003c\/li\u003e\n\u003cli\u003eEliminate human subjectivity from fibre optic connector end-face measurements\u003c\/li\u003e\n\u003cli\u003eSave fibre optic connector end-face views during certification process\u003c\/li\u003e\n\u003cli\u003eVersiv™ modular design supports copper certification, fibre optic loss, OTDR testing and fibre end-face inspection\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePerfect for fibre inspection\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003eFibre optic connector end-face contamination is a leading cause of fibre failures. Dirt and contaminant cause insertion loss and back-reflection that inhibits optical transmission and causes havoc with transceivers. Fibre loss and OTDR testing can expose this problem, but in many cases, dirty connections make fibre testing time consuming and inaccurate.\u003c\/p\u003e\n\u003cp\u003eSince dirt can be an issue before, during, or after fibre optic certification testing, and migrate from one fibre optic connector end-face to another upon mating, both sides of any connection must always be cleaned and inspected. Further, mating contaminated fibre optic connectors can cause permanent damage as microscopic debris is crushed between end-faces in physical contact. Even factory terminated patch cords or pigtails must be inspected as protective caps do not keep fibre optic connector end-faces clean. Avoiding this common cause of failure, starts with inspecting the fibre optic connector end-face and eliminating any contamination before insertion into a bulkhead or piece of equipment.\u003c\/p\u003e\n\u003cp\u003eThe FI-7000 FiberInspector Pro is a fibre optic inspection scope that allows you to inspect and certify fibre optic connector end-faces in 1 seconds so you can get the job done the first time. This fibre optic inspection scope provides automated PASS\/FAIL certification take the guess work out of fibre inspection so anyone can be a fibre expert.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFiber Inspection Certification\u003c\/li\u003e\n\u003cli\u003eGraphical indication of Problem Areas\u003c\/li\u003e\n\u003cli\u003eStore End-face Images\u003c\/li\u003e\n\u003cli\u003eBuilt on the Versiv Platform\u003c\/li\u003e\n\u003cli\u003eVersiv’s ProjX™ System\u003c\/li\u003e\n\u003cli\u003eTaptive™ User Interface\u003c\/li\u003e\n\u003cli\u003eLinkWare™ Live Test Results Management Service\u003c\/li\u003e\n\u003cli\u003eLinkWare™ Management Software\u003c\/li\u003e\n\u003cli\u003ePASS\/FAIL Fiber End-face Grading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"product-feature-title ui-accordion-header ui-helper-reset ui-state-default ui-corner-all ui-accordion-icons\" role=\"tab\" id=\"ui-accordion-1-header-1\" aria-controls=\"ui-accordion-1-panel-1\" aria-selected=\"false\" tabindex=\"-1\"\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable0\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInspection Probe specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2M pixels\u003c\/td\u003e\n\u003ctd\u003eBlue LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eBlue LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower source\u003c\/td\u003e\n\u003ctd\u003eVersiv mainframe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eField of View (FOV)\u003c\/td\u003e\n\u003ctd\u003eHorizontal: 425 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVertical: 320 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum detectable particle size\u003c\/td\u003e\n\u003ctd\u003e0.5 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 6.75 in x 1.5 in (1175 mm x 35 mm) without adapter tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003eOperating: 32°F to 122°F (0 °C to +50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage: -4°F to +158°F (-20°C to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eMainframe with module and battery: 3 lbs, 5 oz (1.28 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eMainframe with module and battery: 2.625 in x 5.25 in x 11.0 in ( 6.67 cm x 13.33 cm x 27.94 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eLithium ion battery pack, 7.2 volts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003eEleven hour with Inspection probe attached\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharge Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTester Off\u003c\/td\u003e\n\u003ctd\u003eFour hours to charge from 10% to 90% capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTester On\u003c\/td\u003e\n\u003ctd\u003eSix hours to charge from 10% to 90% capacity with the tester on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature*\u003c\/td\u003e\n\u003ctd\u003e-18ºC to 45ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating temperature\u003c\/td\u003e\n\u003ctd\u003e-30ºC to 60ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e4,000 m (13123 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3200 m (10,500 ft) with ac adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e* Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":2526922407968,"sku":"FI2-7000 INT","price":4472.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/FI-7000_FiberInspector_Pro.jpg?v=1567584736"},{"product_id":"visifault-visual-fault-locator-cable-continuity-tester","title":"Fluke Networks VisiFault™ Visual Fault Locator - VISIFAULT","description":"\u003cp\u003eFluke Networks VisiFault™ Visual Fault Locator - VISIFAULT.\u003c\/p\u003e\n\u003cp\u003eYou can diagnose and repair simple fiber link problems with\u003cspan\u003e \u003c\/span\u003eFluke Networks'\u003cspan\u003e \u003c\/span\u003eVisiFault\u003csup\u003eTM\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVisual Fault Locator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(VFL). The laser-powered VisiFault Visual Fault Locator is a cable continuity tester that locates fibers, verifies cable continuity and polarity. This cable continuity tester helps find breaks in cables, connectors and splices. Continuous and flashing modes make for easier identification. Compatible with 2.5mm and 1.25mm connectors for easy connection. Ruggedly constructed for demanding field-testing. This visual fault locator has a long battery life for hours of use.\u003c\/p\u003e\n\u003cp\u003eVisual fault locator cable continuity tester locates fibres, finds faults, verifies continuity and polarity.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eLocates visual faults including tight bends, breaks and bad connectors\u003c\/li\u003e\n\u003cli\u003eAccelerates end-to-end fibre checks\u003c\/li\u003e\n\u003cli\u003eEasily verifies polarity and identifies fibres\u003c\/li\u003e\n\u003cli\u003eFeatures continuous and flashing modes\u003c\/li\u003e\n\u003cli\u003eErgonomic case survives drops, impacts and vibrations\u003c\/li\u003e\n\u003cli\u003eSupports 2.5 mm and 1.25 mm SFF connectors\u003c\/li\u003e\n\u003cli\u003eOver 80 hours of battery life with two AA batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp class=\"col-xs-12 main-page-header\"\u003e\u003cstrong\u003eFibre Optic Test Equipment Adapter for VisiFault Visual Fault Locator with 1.25 mm Ferrules. Click \u003ca title=\"Fluke Visi Fault locator adaptor for 1.25mm\" href=\"https:\/\/www.networktesters.co.uk\/collections\/fibre-testers\/products\/fibre-optic-test-equipment-adapter\"\u003eHERE\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFibre Verification and Fault Location\u003c\/li\u003e\n\u003cli\u003eEasy To Use\u003c\/li\u003e\n\u003cli\u003eRugged construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp aria-selected=\"false\" aria-controls=\"ui-accordion-1-panel-1\" id=\"ui-accordion-1-header-1\" role=\"tab\" class=\"product-feature-title ui-accordion-header ui-helper-reset ui-state-default ui-corner-all ui-accordion-icons\" tabindex=\"-1\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" id=\"SpecTable0\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd colspan=\"2\" class=\"cellPad\"\u003e\u003cstrong\u003eOptical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eFiber compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003eMultimode and Singlemode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eWavelength\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e650 nm (visible wavelength)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eLaser safety rating\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003eClass II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eOutput power\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e\u0026lt; 1.3 mW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eOutput modes\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003eContinuous (steady) and flashing (2-3Hz pulsed)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e3 km multimode, 4 km singlemode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" id=\"SpecTable1\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd colspan=\"2\" class=\"cellPad\"\u003e\u003cstrong\u003eEnvironmental and mechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eOperating temperature\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e0 °C to 40 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eStorage temperature\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e-20 °C to 60 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eRelative humidity\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e95% (10 to 35 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eVibration\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003eRandom, 2g, 5-500 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eShock\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e1 m drop onto all corners and face\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eAltitude\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cp\u003e3000 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" id=\"SpecTable2\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd colspan=\"2\" class=\"cellPad\"\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e157 x 52 x 37 mm (6.2 x 2.0 x 1.3 inch)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eWeight (including batteries)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e0.18 kg (5.7 oz)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eAdapter\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e2.5 mm universal\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eAdapter cap\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003eTethered protective end cap\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eControls\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003eOn\/off, continuous\/flashing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eBattery\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e \u003c\/span\u003etype\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e2 x AA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eBattery\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e \u003c\/span\u003elife\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u0026gt; 80 hours in continuous mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eSafety\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003eCSA C22.2 No. 1010.1 1992, EN 61010-1, CE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003e\u003cb\u003eCarrying Case\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"cellPad\"\u003e\n\u003cp\u003eSoft sided with belt loop\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Fluke Networks VisiFault Fault Locator","offer_id":30247555719,"sku":"VISIFAULT","price":494.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/Fn-VisiFault_01a_s.jpg?v=1567584820"},{"product_id":"fluke-fi-500","title":"Fluke Networks FI-500 FiberInspector Micro - FI-500","description":"\u003cp class=\"body-copy\"\u003eFluke Networks FI-500 FiberInspector Micro - FI-500 removes the hassle associated with inspecting\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003eend faces, especially in low light and high cable density situations. It is very simple to use: Simply plug the cable into the FI-500 and touch the AF button. Within seconds, the\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003eend face comes into sharp, clear view. And if you're working in a difficult to reach place or you can't get the image to stand still, just touch the pause button to freeze the image.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePortBright™ illumination to see ports in dark and dense panels\u003c\/li\u003e\n\u003cli\u003eAutofocus for stable images in a few seconds\u003c\/li\u003e\n\u003cli\u003eLarge display to view single mode and multimode\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003eend faces\u003c\/li\u003e\n\u003cli\u003eIncludes 4 UPC tips (LC, SC, 1.25 mm and 2.50 mm).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FI-500 is designed to simplify the inspection process. The built-in PortBright flashlight helps you find the right port or cable. The small-profile probe fits into tight spots and features push-button controls for simple operation. Autofocus provides a sharp view of the end face in a few seconds, while the pause button freezes the image on the crisp 320 x 240 display for more detailed inspection.\u003c\/p\u003e\n\u003cp\u003eThe FI-500 FiberInspector\u003cspan\u003e \u003c\/span\u003eMicro fills\u003cspan\u003e \u003c\/span\u003ethe gap between a manual scope and a fully automated inspection scope. The FI-500 has the simplicity and practicality of a manual inspection scope, but with advanced features to reduce troubleshooting and inspection time.\u003c\/p\u003e\n\u003cp\u003eManual\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003einspection scopes are simple to use, but they don't work well on patch panels or situations where there is a high density of\u003cspan\u003e \u003c\/span\u003efibre. Holding it up to one eye and closing your other eye is often inconvenient or impractical, especially in a dark room.\u003c\/p\u003e\n\u003cp\u003eFully automatic inspection scopes analyze and grade the cleanliness of\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003econnections which is important for many applications, but\u003cspan\u003e \u003c\/span\u003eanalysis\u003cspan\u003e \u003c\/span\u003eis usually not needed for quick basic troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePortBright™ Illumination and Compact Probe Design\u003c\/li\u003e\n\u003cli\u003eAutofocus\u003c\/li\u003e\n\u003cli\u003eCleaning Kits\u003c\/li\u003e\n\u003cli\u003eWide Variety of UPC and APC Probe Tips\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePerfect for fibre inspection\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan class=\"ui-accordion-header-icon ui-icon ui-icon-plus\"\u003e\u003c\/span\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-page-section column-grid\"\u003e\n\u003cdiv class=\"section-container\"\u003e\n\u003ctable width=\"100%\" id=\"SpecTable3\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range without the power adapter\u003c\/td\u003e\n\u003ctd\u003eOperating: 0 °C to +50 °C\u003cbr\u003eStorage: -30 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range with the power adapter\u003c\/td\u003e\n\u003ctd\u003eOperating: 0 °C to +40 °C\u003cbr\u003eStorage: -20 °C to + 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity range\u003c\/td\u003e\n\u003ctd\u003eOperating: 0% to 95% °C (0 °C to +50 °C) RH non-condensing\u003cbr\u003eStorage: 0% to 95% (35 °C to 45 °C) RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating: 4,000 meters\u003cbr\u003eStorage: 12,000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e2 g, 5 Hz to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e1 meter drop test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 3rd Edition IEC 62133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\" id=\"SpecTable3\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnification\u003c\/td\u003e\n\u003ctd\u003e1x, 2x, 4x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrames per second\u003c\/td\u003e\n\u003ctd\u003e≥12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type*\u003c\/td\u003e\n\u003ctd\u003eRechargeable NiMH, 2 x 1.2V, 2700 mAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life*\u003c\/td\u003e\n\u003ctd\u003e3 hours of continuous probe use\u003cbr\u003e6 hours of typical probe use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge time\u003c\/td\u003e\n\u003ctd\u003e4 hours minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower adapter\u003c\/td\u003e\n\u003ctd\u003eInput: 100 to 240 VAC±10%, 50\/60Hz\u003cbr\u003eOutput: 6 VDC, 3 A maximum Class II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e3.2 inch TFT LCD, 320 x 240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware upgrades\u003c\/td\u003e\n\u003ctd\u003eUpgrades can be installed from a USB drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0, Type A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.5 in x 3.2 in x 1.5 in (140 mm x 80 mm x 39 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.7 oz (275 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cspan\u003e*Tested using Gold Peak GH230AAHC batteries.\u003c\/span\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\" id=\"SpecTable3\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnification\u003c\/td\u003e\n\u003ctd\u003e200x. Zoom function has 1x, 2x and 4x settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCamera type\u003c\/td\u003e\n\u003ctd\u003e5 Megapixel 1\/4-inch CMOS sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of view\u003c\/td\u003e\n\u003ctd\u003e610 μm x 460 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eLED, \u0026gt;100,000 hr life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndface illumination\u003c\/td\u003e\n\u003ctd\u003eCoaxial blue LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort illumination\u003c\/td\u003e\n\u003ctd\u003e2 white LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eSupplied through the USB interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eVideo output through USB 2.0 interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.6 in x 2 in x 0.95 in (117 mm x 51 mm x 23 mm) (length depends on adapter tip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.4 oz (125 g)(with no adapter tip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-page-section column-grid\"\u003e\u003ca name=\"documents\" class=\"toc-anchor\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003ch5 class=\"product-page-section column-grid\"\u003e\u003c\/h5\u003e\n\u003cdiv class=\"product-page-section column-grid\"\u003e\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":2528053690400,"sku":"FI-500","price":2759.75,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/fi-500_ae365a79-fc18-4607-b27a-305a54f0705f.jpg?v=1567584728"},{"product_id":"fluke-ftk1000","title":"Fluke Networks Fiber Test Kits - FTK1000","description":"\u003cp\u003eFluke Networks Fiber Test Kit includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimpliFiber Pro optical power meter\u003c\/li\u003e\n\u003cli\u003e850\/1300 multimode source\u003c\/li\u003e\n\u003cli\u003eCarrying case\u003c\/li\u003e\n\u003cli\u003eSC power-meter adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #0000ff;\"\u003eGot any questions about the Fibre Test Kit? Please call our team during office hours on 01403 756588.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimpliFiber Pro Kit Configurations\u003c\/li\u003e\n\u003cli\u003eFiber Inspection\u003c\/li\u003e\n\u003cli\u003eFiber Cleaning\u003c\/li\u003e\n\u003cli\u003eResults Management\u003c\/li\u003e\n\u003cli\u003eVerify and Locate Faults\u003c\/li\u003e\n\u003cli\u003eUnique Capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable1\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-10º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-20º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e95% (10º C to 35º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003e75% (35º C to 40º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003eUncontrolled \u0026lt;10º C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eEMI, RFI, EMC\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eStandards compliant\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eConforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable2\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eOptical Power Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDetector Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eInGaAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCalibrated Wavelengths\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e+10 to -52 dBm (850 nm)\u003c\/li\u003e\n\u003cli\u003e+10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Linearity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e±0.2 dB (850 nm)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Uncertainty\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.25 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay Resolution, dB or dBm\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e0.01 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Display Units\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003edBm, mW, μW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto-Wavelength Detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eData Storage\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1000 records, multiple wavelengths per record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eExternal Interface\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eUSB, 2.0 full speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eRemovable adapter, SC adapter as default, optional adapters include LC, ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay update rate\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1 reading per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eReference\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eIndividually set for each wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber ID detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\u0026gt; 50 Hours (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e10, 20, 30 or 60 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, low battery icon blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e11.5 oz (325 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power \u0026lt; -45 dBm\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power \u0026gt; 0 dBm and \u0026lt; -55 dBm\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23°C ±2°C, power level -20dBm, continuous wave, 62.5\/125µm at multi mode wavelengths, 9\/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm,\u003cbr\u003e\u003csup\u003e4\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable3\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eMultimode Optical Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCentral Wavelength\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: +\/-30 nm\u003c\/li\u003e\n\u003cli\u003e1300 nm: +\/- 20 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSpectral Width (FWHM)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: 50 nm (typical)\u003c\/li\u003e\n\u003cli\u003e1300 nm: 135 nm (typical)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMinimum Output Power\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850\/1300 nm:\u003cspan\u003e \u003c\/span\u003e\u003cspan face=\"Arial\" size=\"2\"\u003e\u003cspan face=\"Symbol\" size=\"2\"\u003e³\u003c\/span\u003e\u003cspan size=\"2\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-20 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Output Stability\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.1 dB over 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Can be enabled\/disabled by\u003cspan\u003e \u003c\/span\u003euser.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Output Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Fixed at ID 1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eModes\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eCW, 2 kHz modulated, Auto-wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e40 hrs (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, LED blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1.8 oz (278 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23° C ± 2° C, after 5 minutes warm-up time\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003eauto-wavelength\u003cspan\u003e \u003c\/span\u003emode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":2527173836832,"sku":"FTK1000","price":2671.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/Fn-3326780-ftk2000_02a_moa.jpg?v=1567584755"},{"product_id":"fluke-nfc-kit-case","title":"Fluke Networks Enhanced Fibre Optic Cleaning Kit - NFC-KIT-CASE-E","description":"\u003cp\u003eFluke Networks Enhanced Fibre Optic Cleaning Kit - NFC-KIT-CASE-E offers the complete solution for precision end-face fibre optic cable cleaning.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003eContains everything needed to eliminate the #1 cause of fibre optic link failure: contamination\u003c\/li\u003e\n\u003cli\u003eSupports all fibre connector types in data centre and campus environments\u003c\/li\u003e\n\u003cli\u003eQuick Clean™ Cleaners—no training required! (on specific kits only)\u003c\/li\u003e\n\u003cli\u003eSolvent pen precisely dispenses specially formulated fibre optic cleaning solution\u003c\/li\u003e\n\u003cli\u003eCards for convenient cleaning of fibre end-faces\u003c\/li\u003e\n\u003cli\u003eRugged carrying case stores and transports all fibre optic cleaning tools\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDirt, dust and other contaminants are the enemies of high-speed data transmission over optical fibre. Today's network applications require more bandwidth than ever, making loss budgets tighter than ever. Hence, it is critical that all optical connections are free of contaminants to avoid having application performance issue.\u003c\/p\u003e\n\u003cp\u003eFluke Networks’ Fibre Optic Cleaning Kits contain the best fibre cleaning tools to effectively remove the toughest contaminants in any fibre network. You can choose between the easy-to-use Quick Clean Cleaners, the convenient cleaning cube\/card and the best optic solvent pen to clean both patch cords and fibre end faces inside ports. All fibre optic cleaning materials are lint-free and enable an optimal wet and dry cleaning process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"product-feature-title ui-accordion-header ui-helper-reset ui-state-default ui-accordion-icons ui-accordion-header-active ui-state-active ui-corner-top ui-state-hover ui-state-focus\" role=\"tab\" id=\"ui-accordion-1-header-2\" aria-controls=\"ui-accordion-1-panel-2\" aria-selected=\"true\" tabindex=\"0\"\u003e\u003cstrong\u003eSpecialized Solvent\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" id=\"ui-accordion-1-panel-2\" aria-labelledby=\"ui-accordion-1-header-2\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan id=\"lblBody\"\u003eFor years isopropyl alcohol (IPA) was used to clean fibre end-faces, but now there are customized solvents that are far superior, such as Fluke Networks’ Fiber Optic Solvent Pen. Most importantly, this specialized solvent is more effective than IPA at dissolving all contaminants, especially non-ionic compounds such as buffer gel and pulling lube. You will get a better clean every time and with every contaminant.\u003cbr\u003e\u003cbr\u003eNext, our solvent has a lower surface tension than IPA that allows it to envelop particles and debris, effectively lifting them from the surface of the end-face as they are carried away by a wipe or swab. Many smaller particles carry a charge that bonds them to the ferrule or an end-face. Unlike IPA, this solvent is oxygenated to neutralize this charge so that the charged particle can be removed and more particles are not attracted onto the end-face. When cleaning end-faces inside ports or equipment, the evaporation rate of solvents become significant as it is harder to guarantee removal of all solvent. Fluke Networks’ customized solvent has an evaporation rate tailored to stay long enough to work yet still disappear before mating. It evaporates much faster than IPA. IPA is highly hygroscopic and therefore draws water vapour that can then dry on the end-face and leave a residue, which sometimes appears as a “halo”. Using Fluke Networks’ solvent will avoid this problem.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":2526604492832,"sku":"NFC-KIT-CASE-E","price":321.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/Fn-nfc-kit-case-e_01d_s_1_0_af1e989d-de2c-4e2c-864c-d616d5caf051.jpg?v=1579014241"},{"product_id":"fluke-fi-500tp-apc","title":"Fluke Networks FI-500 FiberInspector - FI-500TP-APC","description":"\u003cp class=\"body-copy\"\u003eFluke Networks FI-500 FiberInspector - FI-500TP-APC .\u003c\/p\u003e\n\u003cp class=\"body-copy\"\u003eThe FI- 500 FiberInspector™ Micro removes the hassle associated with inspecting\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003eend faces, especially in low light and high cable density situations. It is very simple to use: Simply plug the cable into the FI-500 and touch the AF button. Within seconds, the\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003eend face comes into sharp, clear view. And if you're working in a difficult to reach place or you can't get the image to stand still, just touch the pause button to freeze the image.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePortBright™ illumination to see ports in dark and dense panels\u003c\/li\u003e\n\u003cli\u003eAutofocus for stable images in a few seconds\u003c\/li\u003e\n\u003cli\u003eLarge display to view single mode and multimode\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003eend faces\u003c\/li\u003e\n\u003cli\u003eIncludes 4 UPC tips (LC, SC, 1.25 mm and 2.50 mm).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FI-500 is designed to simplify the inspection process. The built-in PortBright flashlight helps you find the right port or cable. The small-profile probe fits into tight spots and features push-button controls for simple operation. Autofocus provides a sharp view of the end face in a few seconds, while the pause button freezes the image on the crisp 320 x 240 display for more detailed inspection.\u003c\/p\u003e\n\u003cp\u003eThe FI-500 FiberInspector\u003cspan\u003e \u003c\/span\u003eMicro fills\u003cspan\u003e \u003c\/span\u003ethe gap between a manual scope and a fully automated inspection scope. The FI-500 has the simplicity and practicality of a manual inspection scope, but with advanced features to reduce troubleshooting and inspection time.\u003c\/p\u003e\n\u003cp\u003eManual\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003einspection scopes are simple to use, but they don't work well on patch panels or situations where there is a high density of\u003cspan\u003e \u003c\/span\u003efibre. Holding it up to one eye and closing your other eye is often inconvenient or impractical, especially in a dark room.\u003c\/p\u003e\n\u003cp\u003eFully automatic inspection scopes analyze and grade the cleanliness of\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003econnections which is important for many applications, but\u003cspan\u003e \u003c\/span\u003eanalysis\u003cspan\u003e \u003c\/span\u003eis usually not needed for quick basic troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePortBright™ Illumination and Compact Probe Design\u003c\/li\u003e\n\u003cli\u003eAutofocus\u003c\/li\u003e\n\u003cli\u003eCleaning Kits\u003c\/li\u003e\n\u003cli\u003eWide Variety of UPC and APC Probe Tips\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePerfect for fibre inspection\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan class=\"ui-accordion-header-icon ui-icon ui-icon-plus\"\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-page-section column-grid\"\u003e\n\u003cdiv class=\"section-container\"\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable3\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range without the power adapter\u003c\/td\u003e\n\u003ctd\u003eOperating: 0 °C to +50 °C\u003cbr\u003eStorage: -30 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range with the power adapter\u003c\/td\u003e\n\u003ctd\u003eOperating: 0 °C to +40 °C\u003cbr\u003eStorage: -20 °C to + 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity range\u003c\/td\u003e\n\u003ctd\u003eOperating: 0% to 95% °C (0 °C to +50 °C) RH non-condensing\u003cbr\u003eStorage: 0% to 95% (35 °C to 45 °C) RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating: 4,000 meters\u003cbr\u003eStorage: 12,000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e2 g, 5 Hz to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003cspan\u003e \u003c\/span\u003edrop test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 3rd Edition IEC 62133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable3\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnification\u003c\/td\u003e\n\u003ctd\u003e1x, 2x, 4x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrames per second\u003c\/td\u003e\n\u003ctd\u003e≥12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type*\u003c\/td\u003e\n\u003ctd\u003eRechargeable NiMH, 2 x 1.2V, 2700 mAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life*\u003c\/td\u003e\n\u003ctd\u003e3 hours of continuous probe use\u003cbr\u003e6 hours of typical probe use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge time\u003c\/td\u003e\n\u003ctd\u003e4 hours minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower adapter\u003c\/td\u003e\n\u003ctd\u003eInput: 100 to 240 VAC±10%, 50\/60Hz\u003cbr\u003eOutput: 6 VDC, 3 A maximum Class II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e3.2 inch TFT LCD, 320 x 240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware upgrades\u003c\/td\u003e\n\u003ctd\u003eUpgrades can be installed from a USB drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0, Type A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.5 in x 3.2 in x 1.5 in (140 mm x 80 mm x 39 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.7 oz (275 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cspan\u003e*Tested using Gold Peak GH230AAHC batteries.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"section-container\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable3\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnification\u003c\/td\u003e\n\u003ctd\u003e200x. Zoom function has 1x, 2x and 4x settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCamera type\u003c\/td\u003e\n\u003ctd\u003e5 Megapixel 1\/4-inch CMOS sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of view\u003c\/td\u003e\n\u003ctd\u003e610 μm x 460 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eLED, \u0026gt;100,000 hr life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndface illumination\u003c\/td\u003e\n\u003ctd\u003eCoaxial blue LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort illumination\u003c\/td\u003e\n\u003ctd\u003e2 white LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eSupplied through the USB interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eVideo output through USB 2.0 interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.6 in x 2 in x 0.95 in (117 mm x 51 mm x 23 mm) (length depends on adapter tip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.4 oz (125 g)(with no adapter tip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":2526858346528,"sku":"FI-500TP-APC","price":694.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/Fn-4820292-fi-500tp-apc_01a_c.jpg?v=1569030231"},{"product_id":"fluke-fi-525","title":"Fluke Networks FI-500 FiberInspector™ - FI-525","description":"\u003cp class=\"body-copy\"\u003eDirty\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003eoptic end faces are the major cause of problems in\u003cspan\u003e \u003c\/span\u003esinglemode\u003cspan\u003e \u003c\/span\u003eand multimode\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003eoptic systems. The FI- 500 FiberInspector™ Micro removes the hassle associated with inspecting\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003eend faces, especially in low light and high cable density situations. It is very simple to use: Simply plug the cable into the FI-500 and touch the AF button. Within seconds, the\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003eend face comes into sharp, clear view. And if you're working in a difficult to reach place or you can't get the image to stand still, just touch the pause button to freeze the image.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePortBright™ illumination to see ports in dark and dense panels\u003c\/li\u003e\n\u003cli\u003eAutofocus for stable images in a few seconds\u003c\/li\u003e\n\u003cli\u003eLarge display to view single mode and multimode\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003eend faces\u003c\/li\u003e\n\u003cli\u003eIncludes 4 UPC tips (LC, SC, 1.25 mm and 2.50 mm).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eToday's high-density\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003epatch panels make inspection a challenge. Finding the cable or port to test can be tough, especially in the low light conditions found in most data\u003cspan\u003e \u003c\/span\u003ecentres\u003cspan\u003e \u003c\/span\u003eand wiring closets.The FI-500 is designed to simplify the inspection process. The built-in PortBright flashlight helps you find the right port or cable. The small-profile probe fits into tight\u003c\/p\u003e\n\u003cp\u003eThe FI-500 is designed to simplify the inspection process. The built-in PortBright flashlight helps you find the right port or cable. The small-profile probe fits into tight spots and features push-button controls for simple operation. Autofocus provides a sharp view of the end face in a few seconds, while the pause button freezes the image on the crisp 320 x 240 display for more detailed inspection.\u003c\/p\u003e\n\u003cp\u003eThe FI-500 FiberInspector\u003cspan\u003e \u003c\/span\u003eMicro fills\u003cspan\u003e \u003c\/span\u003ethe gap between a manual scope and a fully automated inspection scope. The FI-500 has the simplicity and practicality of a manual inspection scope, but with advanced features to reduce troubleshooting and inspection time.\u003c\/p\u003e\n\u003cp\u003eManual\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003einspection scopes are simple to use, but they don't work well on patch panels or situations where there is a high density of\u003cspan\u003e \u003c\/span\u003efibre. Holding it up to one eye and closing your other eye is often inconvenient or impractical, especially in a dark room.\u003c\/p\u003e\n\u003cp\u003eFully automatic inspection scopes analyze and grade the cleanliness of\u003cspan\u003e \u003c\/span\u003efibre\u003cspan\u003e \u003c\/span\u003econnections which is important for many applications, but\u003cspan\u003e \u003c\/span\u003eanalysis\u003cspan\u003e \u003c\/span\u003eis usually not needed for quick basic troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePortBright™ Illumination and Compact Probe Design\u003c\/li\u003e\n\u003cli\u003eAutofocus\u003c\/li\u003e\n\u003cli\u003eCleaning Kits\u003c\/li\u003e\n\u003cli\u003eWide Variety of UPC and APC Probe Tips\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePerfect for fibre inspection\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan class=\"ui-accordion-header-icon ui-icon ui-icon-plus\"\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-page-section column-grid\"\u003e\n\u003cdiv class=\"section-container\"\u003e\n\u003ctable width=\"100%\" id=\"SpecTable3\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range without the power adapter\u003c\/td\u003e\n\u003ctd\u003eOperating: 0 °C to +50 °C\u003cbr\u003eStorage: -30 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range with the power adapter\u003c\/td\u003e\n\u003ctd\u003eOperating: 0 °C to +40 °C\u003cbr\u003eStorage: -20 °C to + 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity range\u003c\/td\u003e\n\u003ctd\u003eOperating: 0% to 95% °C (0 °C to +50 °C) RH non-condensing\u003cbr\u003eStorage: 0% to 95% (35 °C to 45 °C) RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating: 4,000 meters\u003cbr\u003eStorage: 12,000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e2 g, 5 Hz to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003cspan\u003e \u003c\/span\u003edrop test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 3rd Edition IEC 62133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\" id=\"SpecTable3\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnification\u003c\/td\u003e\n\u003ctd\u003e1x, 2x, 4x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrames per second\u003c\/td\u003e\n\u003ctd\u003e≥12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type*\u003c\/td\u003e\n\u003ctd\u003eRechargeable NiMH, 2 x 1.2V, 2700 mAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life*\u003c\/td\u003e\n\u003ctd\u003e3 hours of continuous probe use\u003cbr\u003e6 hours of typical probe use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge time\u003c\/td\u003e\n\u003ctd\u003e4 hours minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower adapter\u003c\/td\u003e\n\u003ctd\u003eInput: 100 to 240 VAC±10%, 50\/60Hz\u003cbr\u003eOutput: 6 VDC, 3 A maximum Class II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e3.2 inch TFT LCD, 320 x 240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware upgrades\u003c\/td\u003e\n\u003ctd\u003eUpgrades can be installed from a USB drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0, Type A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.5 in x 3.2 in x 1.5 in (140 mm x 80 mm x 39 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.7 oz (275 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cspan\u003e*Tested using Gold Peak GH230AAHC batteries.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"section-container\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"section-container\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\" id=\"SpecTable3\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnification\u003c\/td\u003e\n\u003ctd\u003e200x. Zoom function has 1x, 2x and 4x settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCamera type\u003c\/td\u003e\n\u003ctd\u003e5 Megapixel 1\/4-inch CMOS sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of view\u003c\/td\u003e\n\u003ctd\u003e610 μm x 460 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eLED, \u0026gt;100,000 hr life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndface illumination\u003c\/td\u003e\n\u003ctd\u003eCoaxial blue LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort illumination\u003c\/td\u003e\n\u003ctd\u003e2 white LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eSupplied through the USB interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eVideo output through USB 2.0 interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.6 in x 2 in x 0.95 in (117 mm x 51 mm x 23 mm) (length depends on adapter tip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.4 oz (125 g)(with no adapter tip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":2526858444832,"sku":"FI-525","price":3039.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/Fn-4812124-fi-525_01a_moa_b7b70cda-d948-4315-bb3d-0d0c5776cfc2.jpg?v=1569030232"},{"product_id":"fluke-fi-7000-mpo","title":"Fluke Networks FI-7000 FiberInspector™ Pro - FI2-7000 INT","description":"\u003cspan\u003e1-second automated PASS\/FAIL certification of fibre optic connector end-faces with the Fluke Networks FI-7000.\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated Pass\/Fail certification of fibre optic connector end-faces\u003c\/li\u003e\n\u003cli\u003eGraphical indication of problem areas due to contamination, pits, chips, and scratches\u003c\/li\u003e\n\u003cli\u003eCertify to industry standards - IEC 61300-3-35\u003c\/li\u003e\n\u003cli\u003eEliminate human subjectivity from fibre optic connector end-face measurements\u003c\/li\u003e\n\u003cli\u003eSave fibre optic connector end-face views during certification process\u003c\/li\u003e\n\u003cli\u003eVersiv™ modular design supports copper certification, fibre optic loss, OTDR testing and fibre end-face inspection\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePerfect for fibre inspection\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003eFibre optic connector end-face contamination is a leading cause of fibre failures. Dirt and contaminant cause insertion loss and back-reflection that inhibits optical transmission and causes havoc with transceivers. Fibre loss and OTDR testing can expose this problem, but in many cases, dirty connections make fibre testing time consuming and inaccurate.\u003c\/p\u003e\n\u003cp\u003eSince dirt can be an issue before, during, or after fibre optic certification testing, and migrate from one fibre optic connector end-face to another upon mating, both sides of any connection must always be cleaned and inspected. Further, mating contaminated fibre optic connectors can cause permanent damage as microscopic debris is crushed between end-faces in physical contact. Even factory terminated patch cords or pigtails must be inspected as protective caps do not keep fibre optic connector end-faces clean. Avoiding this common cause of failure, starts with inspecting the fibre optic connector end-face and eliminating any contamination before insertion into a bulkhead or piece of equipment.\u003c\/p\u003e\n\u003cp\u003eThe FI-7000 FiberInspector Pro is a fibre optic inspection scope that allows you to inspect and certify fibre optic connector end-faces in 1 seconds so you can get the job done the first time. This fibre optic inspection scope provides automated PASS\/FAIL certification take the guess work out of fibre inspection so anyone can be a fibre expert.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFiber Inspection Certification\u003c\/li\u003e\n\u003cli\u003eGraphical indication of Problem Areas\u003c\/li\u003e\n\u003cli\u003eStore End-face Images\u003c\/li\u003e\n\u003cli\u003eBuilt on the Versiv Platform\u003c\/li\u003e\n\u003cli\u003eVersiv’s ProjX™ System\u003c\/li\u003e\n\u003cli\u003eTaptive™ User Interface\u003c\/li\u003e\n\u003cli\u003eLinkWare™ Live Test Results Management Service\u003c\/li\u003e\n\u003cli\u003eLinkWare™ Management Software\u003c\/li\u003e\n\u003cli\u003ePASS\/FAIL Fiber End-face Grading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"product-feature-title ui-accordion-header ui-helper-reset ui-state-default ui-corner-all ui-accordion-icons\" role=\"tab\" id=\"ui-accordion-1-header-1\" aria-controls=\"ui-accordion-1-panel-1\" aria-selected=\"false\" tabindex=\"-1\"\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable0\" width=\"100%\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInspection Probe specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2M pixels\u003c\/td\u003e\n\u003ctd\u003eBlue LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eBlue LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower source\u003c\/td\u003e\n\u003ctd\u003eVersiv mainframe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eField of View (FOV)\u003c\/td\u003e\n\u003ctd\u003eHorizontal: 425 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVertical: 320 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum detectable particle size\u003c\/td\u003e\n\u003ctd\u003e0.5 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 6.75 in x 1.5 in (1175 mm x 35 mm) without adapter tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003eOperating: 32°F to 122°F (0 °C to +50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage: -4°F to +158°F (-20°C to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eMainframe with module and battery: 3 lbs, 5 oz (1.28 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eMainframe with module and battery: 2.625 in x 5.25 in x 11.0 in ( 6.67 cm x 13.33 cm x 27.94 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eLithium ion battery pack, 7.2 volts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003eEleven hour with Inspection probe attached\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharge Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTester Off\u003c\/td\u003e\n\u003ctd\u003eFour hours to charge from 10% to 90% capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTester On\u003c\/td\u003e\n\u003ctd\u003eSix hours to charge from 10% to 90% capacity with the tester on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature*\u003c\/td\u003e\n\u003ctd\u003e-18ºC to 45ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating temperature\u003c\/td\u003e\n\u003ctd\u003e-30ºC to 60ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e4,000 m (13123 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3200 m (10,500 ft) with ac adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e* Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":2526917820448,"sku":"FI2-7000 INT","price":4472.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/Fn-fi-7000-mpo_01b_c.jpg?v=1569030235"},{"product_id":"fluke-sfmultimodesource","title":"Fluke Networks SimpliFiber® Pro Optical Power Meter - SFMULTIMODESOURCE","description":"\u003cp\u003e\u003cstrong\u003eSimpliFiber® Pro Optical Power Meter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the specifications tab for full details.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #0000ff;\"\u003eGot any questions about the Fluke Networks SimpliFiber® Pro Optical Power Meter? Then call one of our team on 01403 756588\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimpliFiber Pro Kit Configurations\u003c\/li\u003e\n\u003cli\u003eFiber Inspection\u003c\/li\u003e\n\u003cli\u003eFiber Cleaning\u003c\/li\u003e\n\u003cli\u003eResults Management\u003c\/li\u003e\n\u003cli\u003eVerify and Locate Faults\u003c\/li\u003e\n\u003cli\u003eUnique Capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable1\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-10º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-20º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e95% (10º C to 35º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003e75% (35º C to 40º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003eUncontrolled \u0026lt;10º C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eEMI, RFI, EMC\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eStandards compliant\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eConforms to relevant European Union directives; relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable3\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eMultimode Optical Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCentral Wavelength\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: +\/-30 nm\u003c\/li\u003e\n\u003cli\u003e1300 nm: +\/- 20 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSpectral Width (FWHM)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: 50 nm (typical)\u003c\/li\u003e\n\u003cli\u003e1300 nm: 135 nm (typical)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMinimum Output Power\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850\/1300 nm:\u003cspan\u003e \u003c\/span\u003e\u003cspan face=\"Arial\" size=\"2\"\u003e\u003cspan face=\"Symbol\" size=\"2\"\u003e³\u003c\/span\u003e\u003cspan size=\"2\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-20 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Output Stability\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.1 dB over 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Can be enabled\/disabled by\u003cspan\u003e \u003c\/span\u003euser.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Output Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Fixed at ID 1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eModes\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eCW, 2 kHz modulated, Auto-wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e40 hrs (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, LED blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1.8 oz (278 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23° C ± 2° C, after 5 minutes warm-up time\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003eauto-wavelength\u003cspan\u003e \u003c\/span\u003emode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":2527149752352,"sku":"SFMULTIMODESOURCE","price":1438.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/files\/Untitled_design_-_2025-08-12T152619.662.png?v=1755008795"},{"product_id":"fluke-sfpowermeter","title":"Fluke Networks SimpliFiber® Pro Optical Power Meter - SFPOWERMETER","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSimpliFiber® Pro Optical Power Meter\u003c\/strong\u003e\u003cspan\u003e - SFPOWERMETER is a s\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003eimple-to-use fibre-loss tester with advanced time-saving features. \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eVarious kits available with configurations to meet your fibre verification, inspection, and cleaning needs.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimpliFiber Pro Kit Configurations\u003c\/li\u003e\n\u003cli\u003eFiber Inspection\u003c\/li\u003e\n\u003cli\u003eFiber Cleaning\u003c\/li\u003e\n\u003cli\u003eResults Management\u003c\/li\u003e\n\u003cli\u003eVerify and Locate Faults\u003c\/li\u003e\n\u003cli\u003eUnique Capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable1\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-10º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-20º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e95% (10º C to 35º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003e75% (35º C to 40º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003eUncontrolled \u0026lt;10º C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eEMI, RFI, EMC\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eStandards compliant\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eConforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable2\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eOptical Power Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDetector Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eInGaAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCalibrated Wavelengths\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e+10 to -52 dBm (850 nm)\u003c\/li\u003e\n\u003cli\u003e+10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Linearity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e±0.2 dB (850 nm)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Uncertainty\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.25 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay Resolution, dB or dBm\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e0.01 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Display Units\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003edBm, mW, μW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto-Wavelength Detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eData Storage\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1000 records, multiple wavelengths per record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eExternal Interface\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eUSB, 2.0 full speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eRemovable adapter, SC adapter as default, optional adapters include LC, ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay update rate\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1 reading per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eReference\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eIndividually set for each wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber ID detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\u0026gt; 50 Hours (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e10, 20, 30 or 60 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, low battery icon blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e11.5 oz (325 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csup\u003e\u003cbr\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power \u0026lt; -45 dBm\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power \u0026gt; 0 dBm and \u0026lt; -55 dBm\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23°C ±2°C, power level -20dBm, continuous wave, 62.5\/125µm at multi mode wavelengths, 9\/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm,\u003cbr\u003e\u003csup\u003e4\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable3\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCentral Wavelength\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: +\/-30 nm\u003c\/li\u003e\n\u003cli\u003e1300 nm: +\/- 20 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSpectral Width (FWHM)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: 50 nm (typical)\u003c\/li\u003e\n\u003cli\u003e1300 nm: 135 nm (typical)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMinimum Output Power\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850\/1300 nm:\u003cspan\u003e \u003c\/span\u003e\u003cspan face=\"Arial\" size=\"2\"\u003e\u003cspan face=\"Symbol\" size=\"2\"\u003e³\u003c\/span\u003e\u003cspan size=\"2\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-20 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Output Stability\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.1 dB over 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Can be enabled\/disabled by\u003cspan\u003e \u003c\/span\u003euser.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Output Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Fixed at ID 1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eModes\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eCW, 2 kHz modulated, Auto-wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e40 hrs (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, LED blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1.8 oz (278 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23° C ± 2° C, after 5 minutes warm-up time\u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003eauto-wavelength\u003cspan\u003e \u003c\/span\u003emode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":2527151226912,"sku":"SFPOWERMETER","price":1561.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/files\/Untitled_design_-_2025-08-12T152509.624.png?v=1755008728"},{"product_id":"fluke-sfsinglemodesource","title":"Fluke Networks SimpliFiber® Pro Optical Power Meter - SFSINGLEMODESOURCE","description":"\u003cp\u003e\u003cspan\u003eFluke Networks singlemode laser light source for the \u003c\/span\u003eSimpliFiber® series.\u003c\/p\u003e\n\u003cp\u003eCheck the Part Number and Specifications tab for full details.\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cstrong\u003eGot any questions? \u003c\/strong\u003e\u003cstrong\u003eCall 01403 756588 during office hours to speak to a team member.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimpliFiber Pro Kit Configurations\u003c\/li\u003e\n\u003cli\u003eFiber Inspection\u003c\/li\u003e\n\u003cli\u003eFiber Cleaning\u003c\/li\u003e\n\u003cli\u003eResults Management\u003c\/li\u003e\n\u003cli\u003eVerify and Locate Faults\u003c\/li\u003e\n\u003cli\u003eUnique Capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable1\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-10º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-20º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e95% (10º C to 35º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003e75% (35º C to 40º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003eUncontrolled \u0026lt;10º C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eEMI, RFI, EMC\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eStandards compliant\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eConforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable4\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eSinglemode Optical Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310 nm\/1550 nm: dual FP laser\u003cbr\u003e1490 nm\/1625 nm: dual DFB laser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCentral wavelength\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: ±20 nm\u003c\/li\u003e\n\u003cli\u003e1550 nm: ±30 nm\u003c\/li\u003e\n\u003cli\u003e1490 nm: ±3 nm\u003c\/li\u003e\n\u003cli\u003e1625 nm: ±5 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: +\/- 20 nm\u003c\/li\u003e\n\u003cli\u003e1550 nm: +\/- 30 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSpectral width (RMS)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: 2 nm (maximum)\u003c\/li\u003e\n\u003cli\u003e1550 nm: 3 nm (maximum)\u003c\/li\u003e\n\u003cli\u003e1490 nm\/1625 nm: 1 nm (maximum)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMinimum output power\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310\/1550 nm ≥ -7dBm (typical)\u003cbr\u003e1490 nm\/1625 nm: ≥ -3 dBm (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Output Stability\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.25 dB over 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Can be enabled or disabled by\u003cspan\u003e \u003c\/span\u003euser.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLaunch Condition\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e9\/125 μm\u003cspan\u003e \u003c\/span\u003efibre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310\/1550 source is fixed at ID 2\u003cbr\u003e1490 nm\/1625 nm is fixed at ID 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eModes\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eCW, 2 kHz modulated, Auto-wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 hrs (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes (can be enabled or disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED blinks.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e9.8 oz (278 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csup\u003e\u003cbr\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23° C ± 2° C, after 5 minutes warm-up time\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003eauto-wavelength\u003cspan\u003e \u003c\/span\u003emode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":2527167610912,"sku":"SFSINGLEMODESOURCE","price":2798.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/files\/Untitled_design_-_2025-08-12T152332.531.png?v=1755008653"},{"product_id":"fluke-ftk1475","title":"Fluke Networks Fiber Test Kits - FTK1475","description":"\u003cp\u003eFluke Networks Fiber Test Kits - FTK1475; Complete Fiber Verification Kit with FI-500 FiberInspector Micro – Includes SimpliFiber Pro optical power meter, 850\/1300 multimode source, 1310\/1550 singlemode source, VisiFault VFL, FI-500 FiberInspector, two (2) FindFiber Remote ID sources, and carrying case; SC, ST, and LC power meter adapters, NFC-KIT-BOX fiber optic cleaning kit.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimpliFiber Pro Kit Configurations\u003c\/li\u003e\n\u003cli\u003eFiber Inspection\u003c\/li\u003e\n\u003cli\u003eFiber Cleaning\u003c\/li\u003e\n\u003cli\u003eResults Management\u003c\/li\u003e\n\u003cli\u003eVerify and Locate Faults\u003c\/li\u003e\n\u003cli\u003eUnique Capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable1\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-10º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-20º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e95% (10º C to 35º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003e75% (35º C to 40º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003eUncontrolled \u0026lt;10º C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eEMI, RFI, EMC\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eStandards compliant\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eConforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable2\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eOptical Power Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDetector Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eInGaAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCalibrated Wavelengths\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e+10 to -52 dBm (850 nm)\u003c\/li\u003e\n\u003cli\u003e+10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Linearity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e±0.2 dB (850 nm)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Uncertainty\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.25 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay Resolution, dB or dBm\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e0.01 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Display Units\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003edBm, mW, μW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto-Wavelength Detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eData Storage\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1000 records, multiple wavelengths per record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eExternal Interface\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eUSB, 2.0 full speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eRemovable adapter, SC adapter as default, optional adapters include LC, ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay update rate\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1 reading per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eReference\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eIndividually set for each wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber ID detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\u0026gt; 50 Hours (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e10, 20, 30 or 60 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, low battery icon blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e11.5 oz (325 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power \u0026lt; -45 dBm\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power \u0026gt; 0 dBm and \u0026lt; -55 dBm\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23°C ±2°C, power level -20dBm, continuous wave, 62.5\/125µm at multi mode wavelengths, 9\/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm,\u003cbr\u003e\u003csup\u003e4\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable3\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eMultimode Optical Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCentral Wavelength\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: +\/-30 nm\u003c\/li\u003e\n\u003cli\u003e1300 nm: +\/- 20 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSpectral Width (FWHM)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: 50 nm (typical)\u003c\/li\u003e\n\u003cli\u003e1300 nm: 135 nm (typical)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMinimum Output Power\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850\/1300 nm:\u003cspan\u003e \u003c\/span\u003e\u003cspan face=\"Arial\" size=\"2\"\u003e\u003cspan face=\"Symbol\" size=\"2\"\u003e³\u003c\/span\u003e\u003cspan size=\"2\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-20 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Output Stability\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.1 dB over 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Can be enabled\/disabled by\u003cspan\u003e \u003c\/span\u003euser.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Output Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Fixed at ID 1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eModes\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eCW, 2 kHz modulated, Auto-wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e40 hrs (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, LED blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1.8 oz (278 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23° C ± 2° C, after 5 minutes warm-up time\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003eauto-wavelength\u003cspan\u003e \u003c\/span\u003emode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable4\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eSinglemode Optical Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310 nm\/1550 nm: dual FP laser\u003cbr\u003e1490 nm\/1625 nm: dual DFB laser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCentral wavelength\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: ±20 nm\u003c\/li\u003e\n\u003cli\u003e1550 nm: ±30 nm\u003c\/li\u003e\n\u003cli\u003e1490 nm: ±3 nm\u003c\/li\u003e\n\u003cli\u003e1625 nm: ±5 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: +\/- 20 nm\u003c\/li\u003e\n\u003cli\u003e1550 nm: +\/- 30 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSpectral width (RMS)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: 2 nm (maximum)\u003c\/li\u003e\n\u003cli\u003e1550 nm: 3 nm (maximum)\u003c\/li\u003e\n\u003cli\u003e1490 nm\/1625 nm: 1 nm (maximum)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMinimum output power\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310\/1550 nm ≥ -7dBm (typical)\u003cbr\u003e1490 nm\/1625 nm: ≥ -3 dBm (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Output Stability\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.25 dB over 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Can be enabled or disabled by\u003cspan\u003e \u003c\/span\u003euser.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLaunch Condition\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e9\/125 μm\u003cspan\u003e \u003c\/span\u003efibre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310\/1550 source is fixed at ID 2\u003cbr\u003e1490 nm\/1625 nm is fixed at ID 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eModes\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eCW, 2 kHz modulated, Auto-wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 hrs (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes (can be enabled or disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED blinks.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e9.8 oz (278 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23° C ± 2° C, after 5 minutes warm-up time\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003eauto-wavelength\u003cspan\u003e \u003c\/span\u003emode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable5\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eFindFiber Source Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLaser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSource Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1 through 8.\u003cspan\u003e \u003c\/span\u003eDefault\u003cspan\u003e \u003c\/span\u003eis 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower On\/Low-battery Indicator\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\u0026gt; 80 Hours (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e7.1 in x 1.3 in x 1.0 in (17.9 cm x 3.2 cm x 2.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e4.4 oz (125 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSafety\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eMeets Class 1 CDRH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":2527170887712,"sku":"FTK1475","price":9772.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/Fn-4812160-ftk1475_01a_moa.jpg?v=1569030254"},{"product_id":"fluke-ftk1375","title":"Fluke Networks Fiber Test Kits - FTK1375","description":"\u003cp\u003e\u003cspan\u003eFluke Networks Fiber Test Kits - FTK1375; \u003c\/span\u003e\u003cspan\u003eMultimode Fiber Verification Kit with FI-500 FiberInspector Micro. Includes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSimpliFiber Pro optical power meter, 850\/1300 multimode source, VisiFault VFL, FI-500 FiberInspector, FindFiber Remote ID source, and carrying case; SC, ST, and LC power meter adapters\u003c\/span\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\" data-mce-style=\"color: #0000ff;\"\u003e\u003cstrong\u003eGot any questions about the Fluke Networks Fibre Test Kit FTK 1375? Please call our team during office hours on 01403 756588\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimpliFiber Pro Kit Configurations\u003c\/li\u003e\n\u003cli\u003eFiber Inspection\u003c\/li\u003e\n\u003cli\u003eResults Management\u003c\/li\u003e\n\u003cli\u003eVerify and Locate Faults\u003c\/li\u003e\n\u003cli\u003eUnique Capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable1\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-10º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-20º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e95% (10º C to 35º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003e75% (35º C to 40º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003eUncontrolled \u0026lt;10º C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eEMI, RFI, EMC\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eStandards compliant\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eConforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable2\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eOptical Power Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDetector Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eInGaAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCalibrated Wavelengths\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e+10 to -52 dBm (850 nm)\u003c\/li\u003e\n\u003cli\u003e+10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Linearity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e±0.2 dB (850 nm)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Uncertainty\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.25 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay Resolution, dB or dBm\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e0.01 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Display Units\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003edBm, mW, μW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto-Wavelength Detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eData Storage\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1000 records, multiple wavelengths per record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eExternal Interface\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eUSB, 2.0 full speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eRemovable adapter, SC adapter as default, optional adapters include LC, ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay update rate\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1 reading per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eReference\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eIndividually set for each wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber ID detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\u0026gt; 50 Hours (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e10, 20, 30 or 60 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, low battery icon blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e11.5 oz (325 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power \u0026lt; -45 dBm\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power \u0026gt; 0 dBm and \u0026lt; -55 dBm\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23°C ±2°C, power level -20dBm, continuous wave, 62.5\/125µm at multi mode wavelengths, 9\/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm,\u003cbr\u003e\u003csup\u003e4\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable3\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eMultimode Optical Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCentral Wavelength\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: +\/-30 nm\u003c\/li\u003e\n\u003cli\u003e1300 nm: +\/- 20 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSpectral Width (FWHM)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e850 nm: 50 nm (typical)\u003c\/li\u003e\n\u003cli\u003e1300 nm: 135 nm (typical)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMinimum Output Power\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850\/1300 nm:\u003cspan\u003e \u003c\/span\u003e\u003cspan face=\"Arial\" size=\"2\"\u003e\u003cspan face=\"Symbol\" size=\"2\"\u003e³\u003c\/span\u003e\u003cspan size=\"2\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-20 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Output Stability\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.1 dB over 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Can be enabled\/disabled by\u003cspan\u003e \u003c\/span\u003euser.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Output Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Fixed at ID 1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eModes\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eCW, 2 kHz modulated, Auto-wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e40 hrs (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, LED blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1.8 oz (278 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23° C ± 2° C, after 5 minutes warm-up time\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003eauto-wavelength\u003cspan\u003e \u003c\/span\u003emode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable5\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eFindFiber Source Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLaser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSource Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1 through 8.\u003cspan\u003e \u003c\/span\u003eDefault\u003cspan\u003e \u003c\/span\u003eis 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower On\/Low-battery Indicator\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\u0026gt; 80 Hours (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e7.1 in x 1.3 in x 1.0 in (17.9 cm x 3.2 cm x 2.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e4.4 oz (125 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eSafety\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eMeets Class 1 CDRH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":2527171674144,"sku":"FTK1375","price":6450.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/Fn-4812151-ftk1375_01b_c.jpg?v=1569030254"},{"product_id":"fluke-ftk2000","title":"Fluke Networks Fiber Test Kits - FTK2000","description":"\u003cp\u003e\u003cspan\u003eFluke Networks Fiber Test Kits - FTK2000; Singlemode Fiber Verification Kit – Includes SimpliFiber Pro optical power meter, 1310\/1550 singlemode source, carrying case, and SC power-meter adapter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cstrong\u003eGot any questions about the Fluke Networks Fiber Test Kits - FTK2000? Please call our team for help during office hours on 01403 756588\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimpliFiber Pro Kit Configurations\u003c\/li\u003e\n\u003cli\u003eResults Management\u003c\/li\u003e\n\u003cli\u003eUnique Capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable1\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-10º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e-20º C to 50º C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e95% (10º C to 35º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003e75% (35º C to 40º C) Non-Condensing\u003c\/li\u003e\n\u003cli\u003eUncontrolled \u0026lt;10º C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eEMI, RFI, EMC\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eStandards compliant\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eConforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable2\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eOptical Power Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDetector Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eInGaAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCalibrated Wavelengths\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e+10 to -52 dBm (850 nm)\u003c\/li\u003e\n\u003cli\u003e+10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Linearity\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e±0.2 dB (850 nm)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Measurement Uncertainty\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.25 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay Resolution, dB or dBm\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e0.01 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Display Units\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003edBm, mW, μW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto-Wavelength Detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eData Storage\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1000 records, multiple wavelengths per record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eExternal Interface\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eUSB, 2.0 full speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eRemovable adapter, SC adapter as default, optional adapters include LC, ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eDisplay update rate\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1 reading per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eReference\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eIndividually set for each wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber ID detection\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\u0026gt; 50 Hours (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e10, 20, 30 or 60 minutes (can be disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes, low battery icon blinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e11.5 oz (325 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power \u0026lt; -45 dBm\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power \u0026gt; 0 dBm and \u0026lt; -55 dBm\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23°C ±2°C, power level -20dBm, continuous wave, 62.5\/125µm at multi mode wavelengths, 9\/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm,\u003cbr\u003e\u003csup\u003e4\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eFor measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" id=\"SpecTable4\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tableHead\"\u003e\n\u003ctd class=\"cellPad\" colspan=\"2\"\u003e\u003cstrong\u003eSinglemode Optical Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eEmitter Type\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310 nm\/1550 nm: dual FP laser\u003cbr\u003e1490 nm\/1625 nm: dual DFB laser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eCentral wavelength\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: ±20 nm\u003c\/li\u003e\n\u003cli\u003e1550 nm: ±30 nm\u003c\/li\u003e\n\u003cli\u003e1490 nm: ±3 nm\u003c\/li\u003e\n\u003cli\u003e1625 nm: ±5 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: +\/- 20 nm\u003c\/li\u003e\n\u003cli\u003e1550 nm: +\/- 30 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSpectral width (RMS)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm: 2 nm (maximum)\u003c\/li\u003e\n\u003cli\u003e1550 nm: 3 nm (maximum)\u003c\/li\u003e\n\u003cli\u003e1490 nm\/1625 nm: 1 nm (maximum)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eMinimum output power\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310\/1550 nm ≥ -7dBm (typical)\u003cbr\u003e1490 nm\/1625 nm: ≥ -3 dBm (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Output Stability\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e±0.25 dB over 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eAuto Dual-Wavelength Switching\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eYes. Can be enabled or disabled by\u003cspan\u003e \u003c\/span\u003euser.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eOptical Connector\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eFixed SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLaunch Condition\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e9\/125 μm\u003cspan\u003e \u003c\/span\u003efibre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eFindFiber Code Generation\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e1310\/1550 source is fixed at ID 2\u003cbr\u003e1490 nm\/1625 nm is fixed at ID 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eModes\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eCW, 2 kHz modulated, Auto-wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e2 AA Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eBattery Life\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 hrs (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e30 minutes (can be enabled or disabled by user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eLow Battery Warning\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003eLED blinks.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\n\u003ctd class=\"cellPad\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trRegular\"\u003e\n\u003ctd class=\"cellPad\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"cellPad\"\u003e9.8 oz (278 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"trAlternate\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e23° C ± 2° C, after 5 minutes warm-up time\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003eauto-wavelength\u003cspan\u003e \u003c\/span\u003emode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":2527172296736,"sku":"FTK2000","price":4005.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/Fn-3326780-ftk2000_02a_moa_351e083d-cdb3-4604-bb99-e19ddfd6b5a5.jpg?v=1567584762"},{"product_id":"fluke-networks-fibre-optic-cleaning-kit-nfc-kit-case","title":"Fluke Networks Fibre Optic Cleaning Kit - NFC-KIT-CASE","description":"\u003cp\u003eThese Fluke Networks cleaning kits offer the complete solution for precision end-face fibre optic cable cleaning.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003eContains everything needed to eliminate the #1 cause of fibre optic link failure: contamination\u003c\/li\u003e\n\u003cli\u003eSupports all fibre connector types in data centre and campus environments\u003c\/li\u003e\n\u003cli\u003eQuick Clean™ Cleaners—no training required! \u003cspan\u003e(on specific kits only)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSolvent pen precisely dispenses specially formulated fibre optic cleaning solution\u003c\/li\u003e\n\u003cli\u003eCards for convenient cleaning of fibre end-faces\u003c\/li\u003e\n\u003cli\u003eRugged carrying case stores and transports all fibre optic cleaning tools\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDirt, dust and other contaminants are the enemies of high-speed data transmission over optical fibre. Today's network applications require more bandwidth than ever, making loss budgets tighter than ever. Hence, it is critical that all optical connections are free of contaminants to avoid having application performance issue.\u003c\/p\u003e\n\u003cp\u003eFluke Networks’ Fibre Optic Cleaning Kits contain the best fibre cleaning tools to effectively remove the toughest contaminants in any fibre network. You can choose between the easy-to-use Quick Clean Cleaners, the convenient cleaning cube\/card and the best optic solvent pen to clean both patch cords and fibre end faces inside ports. All fibre optic cleaning materials are lint-free and enable an optimal wet and dry cleaning process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"product-feature-title ui-accordion-header ui-helper-reset ui-state-default ui-accordion-icons ui-accordion-header-active ui-state-active ui-corner-top ui-state-hover ui-state-focus\" role=\"tab\" id=\"ui-accordion-1-header-2\" aria-controls=\"ui-accordion-1-panel-2\" aria-selected=\"true\" tabindex=\"0\"\u003e\u003cstrong\u003eSpecialized Solvent\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" id=\"ui-accordion-1-panel-2\" aria-labelledby=\"ui-accordion-1-header-2\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan id=\"lblBody\"\u003eFor years isopropyl alcohol (IPA) was used to clean fibre end-faces, but now there are customized solvents that are far superior, such as Fluke Networks’ Fiber Optic Solvent Pen. Most importantly, this specialized solvent is more effective than IPA at dissolving all contaminants, especially non-ionic compounds such as buffer gel and pulling lube. You will get a better clean every time and with every contaminant.\u003cbr\u003e\u003cbr\u003eNext, our solvent has a lower surface tension than IPA that allows it to envelop particles and debris, effectively lifting them from the surface of the end-face as they are carried away by a wipe or swab. Many smaller particles carry a charge that bonds them to the ferrule or an end-face. Unlike IPA, this solvent is oxygenated to neutralize this charge so that the charged particle can be removed and more particles are not attracted onto the end-face. When cleaning end-faces inside ports or equipment, the evaporation rate of solvents become significant as it is harder to guarantee removal of all solvent. Fluke Networks’ customized solvent has an evaporation rate tailored to stay long enough to work yet still disappear before mating. It evaporates much faster than IPA. IPA is highly hygroscopic and therefore draws water vapour that can then dry on the end-face and leave a residue, which sometimes appears as a “halo”. Using Fluke Networks’ solvent will avoid this problem.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":12344671010921,"sku":"NFC-KIT-CASE","price":258.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/nfc-kit-case.jpg?v=1579014450"},{"product_id":"fluke-networks-certifiber-pro-cfp-100-m","title":"Fluke Networks CertiFiber® Pro with Gold Support- CFP2-100-Q-GLD","description":"\u003cp\u003e\u003cspan\u003eThe Fluke Networks CertiFiber ProQ improves the efficiency of fibre optics certification and includes 1 Versiv Mainframe \u0026amp; Remote and 2 CertiFiber Pro Multimode OLTS Modules. The Taptive user interface simplifies set-up, eliminates errors and speeds troubleshooting. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eVersiv enables users to accomplish more than ever before with a cable tester, accelerating every step of the testing process\u003c\/li\u003e\n\u003cli\u003eProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time.\u003c\/li\u003e\n\u003cli\u003eTaptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels.\u003c\/li\u003e\n\u003cli\u003eLinkWare management software provides unmatched analysis of test results and professional test reports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eCertiFiber Pro’s Optical Loss Test Set (OLTS) double ended fibre optic inspection capability allows you to inspect and certify fiber optic connector end-faces at both ends of your fiber link in less than a second so you can get your job done the first time. This double ended fibre optic inspection capability provides automated PASS\/FAIL certification, takes the guesswork out of fibre inspection so anyone can be a fiber expert.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eGot any questions? \u003c\/strong\u003e\u003cstrong\u003eCall 01403 756588 during office hours to speak to a team member about the Fluke Networks CertiFibre Pro.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOptical loss test set with fastest time to certify – two fibres at two wavelengths in three seconds.\u003c\/li\u003e\n\u003cli\u003eEncircled Flux compliant as required by ANSI\/TIA and ISO\/IEC\u003c\/li\u003e\n\u003cli\u003eMerged Tier 1 (Basic) \/ Tier 2 (Extended) testing and reporting when paired with OptiFiber® Pro OTDR\u003c\/li\u003e\n\u003cli\u003eProjX™ management system ensures all jobs are completed correctly and efficiently\u003c\/li\u003e\n\u003cli\u003eOptical loss test set provides automatic Pass\/Fail analysis to industry standards or custom test limits\u003c\/li\u003e\n\u003cli\u003eDouble ended Pass\/Fail certification of fibre optic connector end faces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" id=\"ui-accordion-1-panel-0\" aria-labelledby=\"ui-accordion-1-header-0\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" aria-labelledby=\"ui-accordion-1-header-1\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" id=\"ui-accordion-1-panel-5\" aria-labelledby=\"ui-accordion-1-header-5\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ctable border=\"0\" cellpadding=\"2\" cellspacing=\"0\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#cccccc\" colspan=\"2\"\u003e\u003cstrong\u003ePower Meter Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003eInterchangeable connector adapter (LC standard, SC, ST and FC optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eDetector Type\u003c\/td\u003e\n\u003ctd\u003eInGaAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eWavelengths\u003c\/td\u003e\n\u003ctd\u003e850 nm, 1300 nm, 1310 nm, 1550 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003ePower Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003ePower Measurement Uncertainty\u003csup\u003e1,2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; +\/- 5% +\/- 32 pW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eMeasurement Linearity\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; ± 0.1 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eRe-calibration Period\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eIntegrated Wi-Fi\u003c\/td\u003e\n\u003ctd\u003eMeets IEEE 802.11 a\/b\/g\/n; dual band (2.4 GHz and 5 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan class=\"legal\"\u003e\u003cspan size=\"1\" style=\"font-size: xx-small;\"\u003e1. +\/- 100 pW at 850 nm\u003cbr\u003e2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50\/125 μm and NA = 0.14 for 9\/125 μm. Ambient temperature 23° ± 1°C. SC\/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST.\u003cbr\u003e3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5 minute warm-up.\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":21664818331753,"sku":"CFP2-100-Q-GLD","price":15785.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/Fn-cfp-100-m.jpg?v=1567584691"},{"product_id":"fluke-networks-certifiber-pro-cfp2-100-s","title":"Fluke Networks CertiFiber® Pro - CFP2-100-S-INT","description":"\u003cp\u003e\u003cspan\u003eThe Fluke Networks CertiFiber ProQI improves the efficiency of fibre optics certification and includes 1 Versiv Mainframe \u0026amp; Remote and 2 CertiFiber Pro Singlemode OLTS modules. The Taptive user interface simplifies set-up, eliminates errors and speeds troubleshooting. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eVersiv enables users to accomplish more than ever before with a cable tester, accelerating every step of the testing process\u003c\/li\u003e\n\u003cli\u003eProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time.\u003c\/li\u003e\n\u003cli\u003eTaptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels.\u003c\/li\u003e\n\u003cli\u003eLinkWare management software provides unmatched analysis of test results and professional test reports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eCertiFiber Pro’s Optical Loss Test Set (OLTS) double ended fibre optic inspection capability allows you to inspect and certify fiber optic connector end-faces at both ends of your fiber link in less than a second so you can get your job done the first time. This double ended fibre optic inspection capability provides automated PASS\/FAIL certification, takes the guesswork out of fibre inspection so anyone can be a fiber expert.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eGot any questions? \u003c\/strong\u003e\u003cstrong\u003eCall 01403 756588 during office hours to speak to a team member about the Fluke Networks CertiFibre Pro.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOptical loss test set with fastest time to certify – two fibres at two wavelengths in three seconds.\u003c\/li\u003e\n\u003cli\u003eEncircled Flux compliant as required by ANSI\/TIA and ISO\/IEC\u003c\/li\u003e\n\u003cli\u003eMerged Tier 1 (Basic) \/ Tier 2 (Extended) testing and reporting when paired with OptiFiber® Pro OTDR\u003c\/li\u003e\n\u003cli\u003eProjX™ management system ensures all jobs are completed correctly and efficiently\u003c\/li\u003e\n\u003cli\u003eOptical loss test set provides automatic Pass\/Fail analysis to industry standards or custom test limits\u003c\/li\u003e\n\u003cli\u003eDouble ended Pass\/Fail certification of fibre optic connector end faces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" id=\"ui-accordion-1-panel-0\" aria-labelledby=\"ui-accordion-1-header-0\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" aria-labelledby=\"ui-accordion-1-header-1\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cdiv class=\"ui-accordion-content ui-helper-reset ui-widget-content ui-corner-bottom ui-accordion-content-active\" id=\"ui-accordion-1-panel-5\" aria-labelledby=\"ui-accordion-1-header-5\" role=\"tabpanel\" aria-expanded=\"true\" aria-hidden=\"false\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ctable border=\"0\" cellpadding=\"2\" cellspacing=\"0\" bordercolor=\"black\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#cccccc\" colspan=\"2\"\u003e\u003cstrong\u003ePower Meter Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003eInterchangeable connector adapter (LC standard, SC, ST and FC optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eDetector Type\u003c\/td\u003e\n\u003ctd\u003eInGaAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eWavelengths\u003c\/td\u003e\n\u003ctd\u003e850 nm, 1300 nm, 1310 nm, 1550 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003ePower Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003ePower Measurement Uncertainty\u003csup\u003e1,2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; +\/- 5% +\/- 32 pW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eMeasurement Linearity\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; ± 0.1 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd\u003eRe-calibration Period\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#f7f7f7\"\u003e\n\u003ctd\u003eIntegrated Wi-Fi\u003c\/td\u003e\n\u003ctd\u003eMeets IEEE 802.11 a\/b\/g\/n; dual band (2.4 GHz and 5 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#efefef\"\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan class=\"legal\"\u003e\u003cspan size=\"1\" style=\"font-size: xx-small;\"\u003e1. +\/- 100 pW at 850 nm\u003cbr\u003e2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50\/125 μm and NA = 0.14 for 9\/125 μm. Ambient temperature 23° ± 1°C. SC\/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST.\u003cbr\u003e3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5 minute warm-up.\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":21664822100073,"sku":"CFP2-100-M","price":12208.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/Fn-cfp-100-s.jpg?v=1568123493"},{"product_id":"fi-3000-fiberinspector-pro-mpo-inspection-camera-fi-3000","title":"Fluke Networks FI-3000 FiberInspector Pro MPO Inspection Camera","description":"\u003cp\u003e\u003cspan\u003eThe FI-3000 FiberInspector Pro offers an extensive feature set that makes testing MPO fiber trunks easy and efficient. The multiple camera design provides an instant Live View with simple touchscreen gestures to move from full trunk to individual endfaces in real time. Automated pass\/fail results in seconds. Store results on your phone and share them through text messages or email or use the industry-leading LinkWare platform to store complete project reports including copper, fiber loss, OTDR, and endface images*. Compact, ergonomic design with autofocus makes it comfortable and fast even when you’re testing hundreds of cables or ports.   \u003c\/span\u003e\u003cem\u003e*Single fiber and Versiv support available second half 2019.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eGet a Grip on More Efficient MPO Inspection:\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eTotal endface visibility with Live View from full trunk to individual endface\u003c\/li\u003e\n\u003cli\u003eIntegrates with Versiv \/ LinkWare for simple operation and documentation or with mobile phones for testing and sharing*\u003c\/li\u003e\n\u003cli\u003eAutomated pass\/fail results in seconds\u003c\/li\u003e\n\u003cli\u003eMultiple Autofocus\/Autocentering Camera design for real time imaging\u003c\/li\u003e\n\u003cli\u003eRugged, ergonomic design with convenient holster\u003c\/li\u003e\n\u003cli\u003eSupports one or two rows of 8,12, or 16 UPC or APC connectors as well as single fibers*.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cstrong\u003eGot a question about the FI-3000 FiberInspector™ Pro MPO Inspection Camera? We're here to help. \u003c\/strong\u003e\u003cstrong\u003eJust call 01403 756588 during office hours to speak to one of our team. \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cstrong\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/uN3m0fmU5jU\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":21676115394665,"sku":"FI-3000","price":5406.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/fn-fi-3000_02a_488x385_561f70e7-e78b-4a60-b428-ad11d6940586.jpg?v=1567584726"},{"product_id":"fluke-networks-dsx2-5000qi-cable-analyzer-dsx2500qi","title":"Fluke Networks DSX2-5000QI INT Cable Analyzer - DSX2-5000QI INT","description":"\u003cp\u003eThe Fluke Networks DSX2-5000Qi Cable Analyzer accelerates the certification process. \u003cbr\u003e Supports copper certification up to Cat 6A, Class EA, fibre optic loss, OTDR testing and fibre end-face inspection. \u003cbr\u003eFluke Networks ProjX system steps through the job requirement from set-up to systems acceptance.\u003c\/p\u003e\nThe Taptive user interface simplifies set-up and eliminates errors and LinkWare management software lets you analyse test results and create professional test reports.\u003cbr\u003e\u003cbr\u003eThe DSX2-5000Qi INT Kit contains:\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e1 Versiv Mainframe \u0026amp; Remote\u003c\/li\u003e\n\u003cli\u003e2 DSX-5000 CableAnalyzer Modules\u003c\/li\u003e\n\u003cli\u003e2 CertiFiber Quad OLTS Modules\u003c\/li\u003e\n\u003cli\u003eSet of Cat 6A\/Class EA Permanent Link Adapters\u003c\/li\u003e\n\u003cli\u003eSet of Cat 6A\/Class EA Channel Adapters\u003c\/li\u003e\n\u003cli\u003e2 Headsets\u003c\/li\u003e\n\u003cli\u003e2 Handstraps\u003c\/li\u003e\n\u003cli\u003e2 Shoulder Straps\u003c\/li\u003e\n\u003cli\u003eCarry Case\u003c\/li\u003e\n\u003cli\u003eUSB Interface Cable\u003c\/li\u003e\n\u003cli\u003eVersiv Open Source Software CD\u003c\/li\u003e\n\u003cli\u003e2 AC Chargers\u003c\/li\u003e\n\u003cli\u003e2 Universal Couplers\u003c\/li\u003e\n\u003cli\u003eUSB Video Inspection Probe w\/ 4 Tips\u003c\/li\u003e\n\u003cli\u003e2 Quick Clean Cleaners (1.25\/2.50 mm)\u003c\/li\u003e\n\u003cli\u003e2 LC\/LC Simplex Adapters\u003c\/li\u003e\n\u003cli\u003eSC\/LC EF-Compliant MM TRC Kit 50 µm\u003c\/li\u003e\n\u003cli\u003eSC\/LC SM TRC Kit\u003c\/li\u003e\n\u003cli\u003eTRC Carry Case\u003c\/li\u003e\n\u003cli\u003eIntegrated Wi-Fi\u003c\/li\u003e\n\u003cli\u003eStatement of Calibration and Getting Started Guides\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003eGot any questions? \u003c\/strong\u003e\u003cstrong\u003eCall 01403 756588 during office hours to speak to a team member about the Fluke Networks DSX-5000Qi.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003e\u003c\/h5\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":31867868872809,"sku":"DSX2-5000Qi INT","price":22532.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/DSX2-5000Qi_INT.png?v=1580984603"},{"product_id":"fluke-networks-dsx2-8000qi-int-cable-analyzer-dsx2-8000qi-int","title":"Fluke Networks DSX2-8000Qi INT Cable Analyzer - DSX2-8000Qi INT","description":"The DSX CableAnalyzer accelerates every step of the certification process thanks to its modular design which supports copper certification, fibre optic loss, OTDR testing and fibre end-face inspection, it's unmatched speed for Cat 6A, 8, Class FA, I\/II and all current standards and Fluke Networks ProjX system which helps to manage job requirements and progress from set-up to systems acceptance, making sure all tests are completed correctly.\u003cbr\u003e\u003cbr\u003eThe Taptive user interface simplifies set-up and eliminates errors and LinkWare management software lets you analyse test results and create professional test reports.\u003cbr\u003e\u003cbr\u003eThe DSX2-8000Qi INT Kit contains:\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e1 Versiv Mainframe \u0026amp; Remote\u003c\/li\u003e\n\u003cli\u003e2 DSX-8000 CableAnalyzer Modules\u003c\/li\u003e\n\u003cli\u003e2 CertiFiber Quad OLTS Modules\u003c\/li\u003e\n\u003cli\u003eSet of Cat 8\/Class I Permanent Link Adapters\u003c\/li\u003e\n\u003cli\u003eSet of Cat 8\/Class I Channel Adapters\u003c\/li\u003e\n\u003cli\u003e2 Headsets\u003c\/li\u003e\n\u003cli\u003e2 Handstraps\u003c\/li\u003e\n\u003cli\u003e2 Shoulder Straps\u003c\/li\u003e\n\u003cli\u003eCarry Case\u003c\/li\u003e\n\u003cli\u003eUSB Interface Cable\u003c\/li\u003e\n\u003cli\u003eVersiv Open Source Software CD\u003c\/li\u003e\n\u003cli\u003e2 AC Chargers\u003c\/li\u003e\n\u003cli\u003e2 Universal Couplers\u003c\/li\u003e\n\u003cli\u003e2 AxTalk Terminators\u003c\/li\u003e\n\u003cli\u003eUSB Video Inspection Probe w\/ 4 Tips\u003c\/li\u003e\n\u003cli\u003e2 Quick Clean Cleaners (1.25\/2.50 mm)\u003c\/li\u003e\n\u003cli\u003e2 LC\/LC Simplex Adapters\u003c\/li\u003e\n\u003cli\u003eSC\/LC EF-Compliant MM TRC Kit 50 µm\u003c\/li\u003e\n\u003cli\u003eSC\/LC SM TRC Kit\u003c\/li\u003e\n\u003cli\u003eTRC Carry Case\u003c\/li\u003e\n\u003cli\u003eIntegrated Wi-Fi\u003c\/li\u003e\n\u003cli\u003eStatement of Calibration and Getting Started Guides\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003eGot any questions? \u003c\/strong\u003e\u003cstrong\u003eCall 01403 756588 during office hours to speak to a team member about the Fluke Networks DSX-8000Qi.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003e\u003c\/h5\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":31867869298793,"sku":"DSX2-8000Qi INT","price":24453.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/DSX2-8000Qi_INT.jpg?v=1580984677"},{"product_id":"fluke-networks-certifiber-pro-cfp-q-add","title":"Fluke Networks CertiFiber Pro Add on Kit - CFP-Q-ADD","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eFluke Networks CertiFiber Pro add on kit improves the efficiency of fibre optics. The Taptive user interface simplifies set-up, eliminates errors and speeds troubleshooting. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eVersiv enables users to accomplish more than ever before with a cable tester, accelerating every step of the testing process\u003c\/li\u003e\n\u003cli\u003eProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time.\u003c\/li\u003e\n\u003cli\u003eTaptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels.\u003c\/li\u003e\n\u003cli\u003eLinkWare management software provides unmatched analysis of test results and professional test reports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke Networks CertiFiber Pro Add on Kit includes\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e2 CertiFiber Pro Quad OLTS Modules\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSC\/LC EF-compliant MM TRC Kit 50 µm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSC\/LC SM TRC Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTRC Carrying Case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e2 LC\/LC Simplex Adaptors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLarge Carry Case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVersiv Open Source Software CD\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStatement of Calibration and Getting Started Guide\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eGot any questions? \u003c\/strong\u003e\u003cstrong\u003eCall 01403 756588 during office hours to speak to a team member about the Fluke Networks CertiFibre Pro.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":31867872149609,"sku":"CFP-Q-ADD","price":11036.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/CFP-Q-ADD.jpg?v=1580984867"},{"product_id":"fluke-networks-optifiber-pro-quad-ofp2-100-q-int","title":"Fluke Networks OptiFiber Pro Quad - OFP2-100-Q INT","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp class=\"lead text-muted\"\u003e\u003cspan\u003eFluke Networks OptiFiber Pro Series OTDRs make novices and experts faster thanks to automated trace analysis and setup which supports applications including data centres, PON and outside plant. Plus, the advanced features of the Fluke Networks OptiFiber include Manual Expert mode, pinch and zoom for in-depth trace analysis and SmartLoop for bi-directional testing. Supports Versiv copper and fibre loss certification modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"collapse show\" id=\"viewmore\"\u003e\n\u003cp\u003eThe Fluke Networks OFP2-100-Q INT Kit contains:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 Versiv 2 Mainframe\u003c\/li\u003e\n\u003cli\u003e1 OptiFiber Pro Quad OTDR module\u003c\/li\u003e\n\u003cli\u003eShoulder Strap\u003c\/li\u003e\n\u003cli\u003eCarry Case\u003c\/li\u003e\n\u003cli\u003eUSB Interface Cable\u003c\/li\u003e\n\u003cli\u003eCarry Case Versiv Open Source Software CD\u003c\/li\u003e\n\u003cli\u003eAC Charger\u003c\/li\u003e\n\u003cli\u003eIntegrated Wi-Fi\u003c\/li\u003e\n\u003cli\u003eStatement of Calibration and Getting Started Guides\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eGot any questions? \u003c\/strong\u003e\u003cstrong\u003eCall 01403 756588 during office hours to speak to a team member about the Fluke Networks OptiFiber Pro.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for Fibre\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eTouch screen\u003c\/li\u003e\n\u003cli\u003eTest result storage\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for network protocol measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":31867877490793,"sku":"OFP2-100-Q INT","price":11581.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/OFP2-100-Q_INT.jpg?v=1580984990"},{"product_id":"fluke-networks-optifiber-pro-quad-add-on-kit-ofp-q-add","title":"Fluke Networks OptiFiber Pro Quad Add on Kit - OFP-Q-ADD","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp class=\"lead text-muted\"\u003eFluke Networks OptiFiber Pro Series OTDRs make novices and experts faster thanks to automated trace analysis and setup which supports applications including data centres, PON and outside plant. Plus, the advanced features of the Fluke Networks OptiFiber include Manual Expert mode, pinch and zoom for in-depth trace analysis and SmartLoop for bi-directional testing. Supports Versiv copper and fibre loss certification modules.\u003cbr\u003e\u003cbr\u003eThe OptiFiber Pro Quad Add on Kit contains: \u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOptiFiber Pro Quad OTDR Module\u003c\/li\u003e\n\u003cli\u003e2 SC\/LC Multimode Launch Cables—50 µm\u003c\/li\u003e\n\u003cli\u003e2 SC\/LC Singlemode Launch Cable—9 µm\u003c\/li\u003e\n\u003cli\u003e2 OTDR source port interchangeable LC adapters\u003c\/li\u003e\n\u003cli\u003eSC\/SC Simplex Adaptor\u003c\/li\u003e\n\u003cli\u003eLC\/LC Simplex Adaptor\u003c\/li\u003e\n\u003cli\u003e2 Launch Fiber Hanging straps and magnets\u003c\/li\u003e\n\u003cli\u003eCarry Case\u003c\/li\u003e\n\u003cli\u003eStatement of Calibration and Getting Started Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"collapse show\" id=\"viewmore\"\u003e\n\u003cul class=\"lead text-muted\"\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eGot any questions? \u003c\/strong\u003e\u003cstrong\u003eCall 01403 756588 during office hours to speak to a team member about the Fluke Networks OptiFiber Pro Add on Kit.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003c\/div\u003e","brand":"Fluke Networks","offers":[{"title":"Default Title","offer_id":31867884142697,"sku":"OFP-Q-ADD","price":9917.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/OFP-Q-ADD.jpg?v=1580985359"},{"product_id":"jonard-tools-visual-fault-locator-kit-jt-vfl-150","title":"Jonard Tools Visual Fault Locator Kit - JT-VFL-150","description":"\u003cmeta charset=\"UTF-8\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Jonard Tools Visual Fault Locator Kit is used for checking the defects of a fibre cable. \u003cspan data-mce-fragment=\"1\"\u003eDesigned to detect fiber breakpoints, fiber leaks, poor connections, and stress points, this visual fault locator is perfect for field personnel detecting faults in fiber optic cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKit Includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVisual Fault Locator\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFC to LC Adapter for VFL-25\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eFeatures:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIncludes adapter for 1.25mm LC connectors\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e650 nm Class IIIA laser diode identifies faults in single and multi-mode fiber up to 3 miles long\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUniversal connector accommodates 2.5mm ferruled connectors, such as FC, SC, and ST connectors\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHas three different modes: Continuous-wave, pulsing, and a slower pulsing mode\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWorks in OTDR dead zones and is used for end-to-end visual fiber identification\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLight and portable pen-style design is perfect for on the go use\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e60 hours of battery life powered by two AAA batteries (included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"table table-bordered\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\" scope=\"row\" class=\"table-active\" data-mce-style=\"text-align: left;\"\u003eFiber Connector\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003eFC, LC, SC, ST\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\" scope=\"row\" class=\"table-active\" data-mce-style=\"text-align: left;\"\u003eLight Source\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003eClass IIIA Laser Diode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\" scope=\"row\" class=\"table-active\" data-mce-style=\"text-align: left;\"\u003eDistance\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003eUp to 5km (3.10 miles)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\" scope=\"row\" class=\"table-active\" data-mce-style=\"text-align: left;\"\u003eWavelength\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003e650nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"table-active\"\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003e-40 Fahrenheit (-40 Celsius) to 185 Fahrenheit (85 Celsius)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"table-active\"\u003eWorking Temperature\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003e-4°F to 140°F (-20°C to 60°C)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\" scope=\"row\" class=\"table-active\" data-mce-style=\"text-align: left;\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003e2 AAA Batteries\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\" scope=\"row\" class=\"table-active\" data-mce-style=\"text-align: left;\"\u003eBattery Life\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003e60 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\" scope=\"row\" class=\"table-active\" data-mce-style=\"text-align: left;\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003e0.16 lbs (72.57g)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\" scope=\"row\" class=\"table-active\" data-mce-style=\"text-align: left;\"\u003eUPC No.\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003e811490016002\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Jonard","offers":[{"title":"Default Title","offer_id":33061652693097,"sku":"JT-VFL-150","price":130.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/Screenshot2021-01-12at10.19.45.png?v=1632918443"},{"product_id":"exfo-optical-power-expert","title":"EXFO Optical Power Expert","description":"\u003cp\u003eEXFO Optical Power expert is state-of-the-art power meter with Bluetooth connectivity. Pocket-sized, with a wide touchscreen and best-in-class optical performances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnect to smart app via Bluetooth for data reporting from the field and cloud storage.\u003c\/li\u003e\n\u003cli\u003eUser-friendly: Compact, colour touchscreen and intuitive interface.\u003c\/li\u003e\n\u003cli\u003eRobust and rugged: IP54 design for dust and water protection.\u003c\/li\u003e\n\u003cli\u003eTime-saving features: no offset nulling, lightning-fast boot-up.\u003c\/li\u003e\n\u003cli\u003eVisual fault locator (on PRO).\u003c\/li\u003e\n\u003cli\u003eLocal data storage of 1000 test results.\u003c\/li\u003e\n\u003cli\u003eError-free, automated wavelength recognition and switching (on PRO).\u003c\/li\u003e\n\u003cli\u003e3-year warranty and calibration interval.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring optical power (dBm) and insertion loss (dB).\u003c\/li\u003e\n\u003cli\u003eFibre tracing.\u003c\/li\u003e\n\u003cli\u003eAll telecoms networks inlc: PON, 5G rollout, FTTX, LAN\/WAN access and enterprise, CATV, military applicatons.\u003c\/li\u003e\n\u003cli\u003eApplicative bundles of wavelengths for PON (GPON, XGS-PON, NG-PON2, RFoG, etc.), CWDM and DWDM ITU channels\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EXFO","offers":[{"title":"HIGH POWER PRO SC  PX1-PRO-H-FOAS-54","offer_id":39836735012969,"sku":"EXF-PX1-PRO-H-FOAS-54","price":880.0,"currency_code":"GBP","in_stock":true},{"title":"HIGH POWER PRO, UNIVERSAL 1.25MM ADAPTOR   PX1-PRO-H-FOAS-U12","offer_id":39836735045737,"sku":"EXF-PX1-PRO-H-FOAS-U12","price":880.0,"currency_code":"GBP","in_stock":true},{"title":"STANDARD POWER PRO SC PX1-PRO-S-FOAS-54","offer_id":39836735078505,"sku":"EXF-PX1-PRO-S-FOAS-54","price":840.0,"currency_code":"GBP","in_stock":true},{"title":"STANDARD POWER PRO UNIVERSAL 1.25MM ADAPTOR  PX1-PRO-S-FOAS-U12","offer_id":39836747137129,"sku":"EXF-PX1-PRO-S-FOAS-U12","price":840.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/px1_1_2000x1667_3212b31b-032c-4162-8b46-923aec0583ee.jpg?v=1643121870"},{"product_id":"jonard-visual-fault-locator-kit-with-1-25mm-and-2-5mm-adaptors","title":"Jonard Visual Fault Locator Kit with 1.25mm and 2.5mm Adaptors","description":"Designed to detect fibre breakpoints, fibre leaks, poor connections, and stress points, this visual fault locator is perfect for field personnel detecting faults in fibre optic cables. \u003cbr\u003eThis VFL Kit features the following:\u003cbr data-mce-fragment=\"1\"\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes adapter for 1.25 mm LC connectors\u003c\/li\u003e\n\u003cli\u003e650 nm Class IIIA laser diode identifies faults in single and multi-mode fibre up to 3 miles long\u003c\/li\u003e\n\u003cli\u003eUniversal connector accommodates 2.5 mm ferruled connectors, such as FC, SC, and ST connectors\u003c\/li\u003e\n\u003cli\u003eHas three different modes: Continuous wave, pulsing, and slower pulsing mode\u003c\/li\u003e\n\u003cli\u003eWorks in OTDR dead zones and is used for end-to-end visual fibre identification\u003c\/li\u003e\n\u003cli\u003eLight and portable pen-style design is perfect for on the go use\u003c\/li\u003e\n\u003cli\u003e60 hours of battery life powered by two AAA batteries (included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eKit includes\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003cul\u003e\n\u003cli\u003eVFL-25 Visual Fault Locator\u003c\/li\u003e\n\u003cli\u003eVFL-25125 FC to LC Adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eFibre Connector: FC, SC, ST \u0026amp; LC\u003cbr\u003eLight Source: Class IIIA Laser Diode\u003cbr\u003eDistance: Up to 5 km (3.10 miles)\u003cbr\u003eWavelength: 650 nm\u003cbr\u003eWorking Temperature: -4°F to 140°F (-20°C to 60°C)\u003cbr\u003eStorage Temperature: -40°F to 185°F (-40°C to 85°C)\u003cbr\u003ePower: 2 AAA Batteries\u003cbr\u003eBattery Life: 60 hours\u003c\/p\u003e","brand":"Jonard","offers":[{"title":"Default Title","offer_id":40831603343465,"sku":"JT-VFL-150","price":129.79,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/JPG_HighResolution_-VFL-150_1_75d31384-f8f9-49a3-8d85-a41e98d8a6ec.jpg?v=1699441431"},{"product_id":"jonard-fibre-optic-power-meter-50-to-26-dbm-with-fc-sc-lc-adapters-1","title":"Jonard Fibre Optic Power Meter (-50 to +26 dBm) With FC\/SC\/LC Adaptors","description":"The Jonard Tools Fibre Optic Power Meter is perfect for measuring both the absolute optical power and relative power loss in fibre optic cables. This power meter features the following:\u003cbr data-mce-fragment=\"1\"\u003e• Measures a wide variety of wavelengths from 800-1650 nm, with a mere 0.01 dB resolution\u003cbr data-mce-fragment=\"1\"\u003e• Measures 6 pre-set calibrated wavelengths with high precision to determine absolute or relative power\u003cbr data-mce-fragment=\"1\"\u003e• Special function of the unit allows the device to be manually calibrated as needed\u003cbr data-mce-fragment=\"1\"\u003e• LED screen is backlit for viewing in low light locations and a 10 minute auto-off helps preserve battery life\u003cbr data-mce-fragment=\"1\"\u003e• Dust-proof button design and shatter-resistant sleeve protect the tool to last a lifetime\u003cbr data-mce-fragment=\"1\"\u003e• Comes with FC, SC, and LC adapters so that fibre connectors can be directly connected to the tool\u003cbr data-mce-fragment=\"1\"\u003e     o The FC\/SC adapters are for APC\/PC\/UPC connectors\u003cbr data-mce-fragment=\"1\"\u003e     o The LC adapter is for PC\/UPC connectors only\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eIncludes:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Fibre Optic Power Meter\u003cbr data-mce-fragment=\"1\"\u003e• Instruction Manual\u003cbr data-mce-fragment=\"1\"\u003e• Protective Cover\u003cbr data-mce-fragment=\"1\"\u003e• (3) AA Batteries (required for operation)\u003cbr data-mce-fragment=\"1\"\u003e• (2) Cleaning Swabs\u003cbr data-mce-fragment=\"1\"\u003e• FC Adapter\u003cbr data-mce-fragment=\"1\"\u003e• LC Adapter\u003cbr data-mce-fragment=\"1\"\u003e• SC Adapter\u003cbr data-mce-fragment=\"1\"\u003e• Nylon Carry Case\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eMeasurement Range: -50 dBm to +26 dBm\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eIncluded Adapters\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eIncluded Adapters: FC, SC, LC\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eConnector Types: FC, SC (APC\/PC\/UPC) \u0026amp; LC (PC\/UPC)\u003cbr data-mce-fragment=\"1\"\u003eCalibrated Wavelengths (nm): 850, 980, 1300, 1310, 1490, 1550, 1625, 1650\u003cbr data-mce-fragment=\"1\"\u003eDetector Type: InGaAs\u003cbr data-mce-fragment=\"1\"\u003eMeasurement Range: -50 dBm to +26 dBm\u003cbr data-mce-fragment=\"1\"\u003eSingle Mode Range: 850, 980, 1300, 1310, 1490, 1550, 1625, 1650 nm, ≤ ± 0.25 dB\u003cbr data-mce-fragment=\"1\"\u003eMulti Mode Range: 850, 1300 nm, ≤ ± 0.8 dB\u003cbr data-mce-fragment=\"1\"\u003eResolution: 0.01 dB\u003cbr data-mce-fragment=\"1\"\u003eOperating Time: ≥ 130 hours\u003cbr data-mce-fragment=\"1\"\u003eBattery Type: (3) AA batteries\u003cbr data-mce-fragment=\"1\"\u003eDimensions: 17.78 cm x 8.26 cm x 2.54 cm\u003cbr data-mce-fragment=\"1\"\u003eWeight: 227g","brand":"Jonard","offers":[{"title":"Default Title","offer_id":40831606325353,"sku":"JT-FPM-50A","price":201.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/JPG_2046x1632_-_FPM-50a_1_03972e7d-ab48-4df4-9afa-66be25610cd5.jpg?v=1699441478"},{"product_id":"jonard-optical-light-source-with-fc-lc-sc-adaptors-for-pc-upc-connectors","title":"Jonard Optical Light Source with FC\/LC\/SC Adaptors For PC\/UPC Connectors","description":"\u003cp\u003eDesigned to provide either 1310nm or 1550nm wavelengths, this optical light source is the perfect tool for providing a stable light source for single mode fibre measurements. This optical light source features the following:\u003cbr data-mce-fragment=\"1\"\u003e • Includes FC, SC, and LC adapters to directly connect to UPC\/PC FC, SC, and LC fibre connectors\u003cbr data-mce-fragment=\"1\"\u003e • Highly stable output power and wavelengths\u003cbr data-mce-fragment=\"1\"\u003e • Has four different modulation outputs (CW, 270 Hz, 1 kHz, 2 kHz) at 1310 N-m and 1550 nm wavelengths\u003cbr data-mce-fragment=\"1\"\u003e • Flush button design makes it easy to use and prevents dust from entering the unit\u003cbr data-mce-fragment=\"1\"\u003e • Shatter-resistant sleeve protects the light source from falls or other damage\u003cbr data-mce-fragment=\"1\"\u003e • Backlit LCD screen provides a clear display, ideal for dark places\u003cbr data-mce-fragment=\"1\"\u003eIncludes:\u003cbr data-mce-fragment=\"1\"\u003e • Fibre Optic Light Source\u003cbr data-mce-fragment=\"1\"\u003e • FC Adapter\u003cbr data-mce-fragment=\"1\"\u003e • LC Adapter\u003cbr data-mce-fragment=\"1\"\u003e • SC Adapter\u003cbr data-mce-fragment=\"1\"\u003e • (2) Cleaning Swabs\u003cbr data-mce-fragment=\"1\"\u003e • (3) AA Batteries (required for operation)\u003cbr data-mce-fragment=\"1\"\u003e • Storage Pouch\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFibre Type\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eFibre Type: Single-mode\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eConnector Types: 1.25 mm LC and 2.5 mm FC\/SC\u003cbr data-mce-fragment=\"1\"\u003eWavelengths (nm): 1310, 1550\u003cbr data-mce-fragment=\"1\"\u003eTypical Output Power: -7 dBm\u003cbr data-mce-fragment=\"1\"\u003eOutput Stability: ± 0.05 dB \/ 15 min or ± 0.1 dB \/ 8 hr\u003cbr data-mce-fragment=\"1\"\u003eOperating Temperature: -10 ± 60°C\u003cbr data-mce-fragment=\"1\"\u003eSpectral Width: ≤ 10 nm\u003cbr data-mce-fragment=\"1\"\u003eModulation Frequencies: CW \/ 270 Hz \/ 1 kHz \/ 2 kHz\u003cbr data-mce-fragment=\"1\"\u003eBattery Type: (3) AA 1.5V alkaline batteries\u003cbr data-mce-fragment=\"1\"\u003eStorage Temperature: -25 ± 70°C\u003cbr data-mce-fragment=\"1\"\u003eDimensions: 17.78cm x 8.10cm x 3.18cm\u003cbr data-mce-fragment=\"1\"\u003eWeight: 304g\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Jonard","offers":[{"title":"Default Title","offer_id":40831606390889,"sku":"JT-FLS-50","price":240.43,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/JPG_HighResolution_-FLS-50_0_02733da8-b561-49fa-a3f0-3c31e5305e37.jpg?v=1699441480"},{"product_id":"jonard-tools-advanced-optical-fibre-identifier","title":"Jonard Tools Advanced Optical Fibre Identifier OFI-100","description":"Quickly identify the direction of light being transmitted in the fibre and display the relative core power without disconnecting the fibre.  Includes a built-in VFL and Power Meter for convenience. This fibre identifier also features the following:\u003cbr data-mce-fragment=\"1\"\u003e• Identifies the traffic direction and frequency (270Hz, 1KHz, 2KHz) with an audible warning\u003cbr data-mce-fragment=\"1\"\u003e• LCD clearly displays the relative core power, signal direction, and battery life\u003cbr data-mce-fragment=\"1\"\u003e• Reversible adapter has one side for 2 mm and 3 mm fibre optic cables, and the opposite side is used for 250 μm and 900μm fibre\u003cbr data-mce-fragment=\"1\"\u003e• Built-in VFL and Power Meter ports for convenient fibre testing\u003cbr data-mce-fragment=\"1\"\u003e• Protective rubber sleeve prevents damage from accidental drops\u003cbr data-mce-fragment=\"1\"\u003e• Lifetime Warranty\u003cbr data-mce-fragment=\"1\"\u003eKit Includes: Advanced Fibre Identifier, adapter for 2.0\/3.0 mm \u0026amp; 250\/900 nm fibres, (2) AA batteries and carrying pouch.","brand":"Jonard","offers":[{"title":"Default Title","offer_id":40998552535145,"sku":"JT-OFI-100","price":621.71,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/PNG_Transparent_Background_-_OFI-100_0_LR_b77d5feb-9250-47ce-886a-7ae44ba246ad.png?v=1704807902"},{"product_id":"jonard-tools","title":"Jonard Tools Optical Fibre Identifier OFI-50","description":"Quickly identify the direction of transmitted fibre and display the relative core power without disconnecting the fibre. This fibre identifier also features the following:\u003cbr data-mce-fragment=\"1\"\u003e• Easy-to-use one key operation\u003cbr data-mce-fragment=\"1\"\u003e• Efficiently identifies the traffic direction and frequency tone (270Hz, 1KHz, 2KHz) with an audible warning.\u003cbr data-mce-fragment=\"1\"\u003e• The display shows you the relative core power clearly\u003cbr data-mce-fragment=\"1\"\u003e• Includes a 3 mm, 2 mm, 900 nm (0.90 mm) and 250 nm (0.25 mm) adapters for different sized fiber optic cables\u003cbr data-mce-fragment=\"1\"\u003e• Included sunshade protects the fiber optic cable from interference to provide more accurate readings\u003cbr data-mce-fragment=\"1\"\u003e• Durable metal housing provides long life and durability\u003cbr data-mce-fragment=\"1\"\u003e• LED indicator lets you know when the 9V battery is running low\u003cbr data-mce-fragment=\"1\"\u003eKit Includes: Fibre Identifier, 3 mm, 2 mm, 900 nm (0.90 mm) and 250 nm (0.25 mm), sunshade, 9V battery, and carrying pouch","brand":"Jonard","offers":[{"title":"Default Title","offer_id":40998552698985,"sku":"JT-OFI-50","price":490.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/PNG_Transparent_Background_-_OFI-50_LR_ab7530e5-3694-4140-8c6d-f48409ac9522.png?v=1704807906"},{"product_id":"jonard-tools-fibre-power-meter-w-data-storage-sm-mm-optical-light-source-kit-fpl-5555","title":"Jonard Tools Fibre Power Meter w\/ Data Storage \u0026 SM\/MM Optical Light Source Kit FPL-5555","description":"This kit provides everything you need to measure using a stable light source for fibre optic cable testing.\u003cbr data-mce-fragment=\"1\"\u003eThis kit includes:\u003cbr data-mce-fragment=\"1\"\u003e• The FPM-55 Fibre Optic Power Meter for measuring wavelengths from 800-1650 nm, with 0.01 dB resolution\u003cbr data-mce-fragment=\"1\"\u003e• Measures 6 pre-set calibrated wavelengths with high precision to determine absolute or relative power\u003cbr data-mce-fragment=\"1\"\u003e• Stores up to 1,000 data entries which can be downloaded via USB\u003cbr data-mce-fragment=\"1\"\u003e• Includes FC\/SC adapters for APC\/PC\/UPC connectors and an LC adapter for PC\/UPC connectors only\u003cbr data-mce-fragment=\"1\"\u003e• The FLS-55 Fibre Optic Light Source for providing a stable light source at 850\/1300 nm for multimode or 1310\/1550\u003cbr data-mce-fragment=\"1\"\u003enm wavelengths single mode fibre measurements\u003cbr data-mce-fragment=\"1\"\u003e• Has four different modulation outputs (CW, 270 Hz, 1 kHz, 2 kHz) at 1310 nm and 1550 nm wavelengths\u003cbr data-mce-fragment=\"1\"\u003e• Includes FC, SC, and LC adapters to directly connect to UPC\/PC FC, SC, and LC fibre connectors\u003cbr data-mce-fragment=\"1\"\u003e• H-22 Rugged Carrying Case with Straps\u003cbr data-mce-fragment=\"1\"\u003e• Nylon Carry Case (FPM-55)\u003cbr data-mce-fragment=\"1\"\u003e• Storage Pouch (FLS-55)\u003cbr data-mce-fragment=\"1\"\u003e• With both the FPM-55 and FLS-55\u003cbr data-mce-fragment=\"1\"\u003e • Instruction Manuals\u003cbr data-mce-fragment=\"1\"\u003e • (3) AA Batteries each (required for operation)\u003cbr data-mce-fragment=\"1\"\u003e • (2) Cleaning Swabs each\u003cbr data-mce-fragment=\"1\"\u003e • FC Adapter, LC Adapter, and SC Adapters","brand":"Jonard","offers":[{"title":"Default Title","offer_id":40998554075241,"sku":"JT-FPL-5555","price":887.36,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/PNG_Transparent_Background_-_FPL-5555_LR_85276397-02fd-4f94-8162-18158d76f319.png?v=1704807921"},{"product_id":"jonard-tools-passive-optical-network-power-meter-bpon-epon-gpon-pon-50","title":"Jonard Tools Passive Optical Network Power Meter (BPON \/ EPON \/ GPON) PON-50","description":"Designed to perform live testing with OLT equipment, this PON Power Meter is perfect for use during FTTx\/PON service tune-up or maintenance. It is able to simultaneously test and measure the signal power of voice, data, and video connections, and is essential for the construction and maintenance of PON systems. This Power Meter also features the\u003cbr data-mce-fragment=\"1\"\u003efollowing:\u003cbr data-mce-fragment=\"1\"\u003e• Includes FC and SC adapters to directly connect to UPC\/PC FC and SC fibre connectors\u003cbr data-mce-fragment=\"1\"\u003e• Analyses voice, data, and video signals in BPON\/EPON\/GPON FTTx systems\u003cbr data-mce-fragment=\"1\"\u003e• Concurrently measures 1310 nm Upstream Burst Signals and 1490\/1550 nm Downstream Signal Measurements\u003cbr data-mce-fragment=\"1\"\u003eanywhere in the network\u003cbr data-mce-fragment=\"1\"\u003e• Three pass, warning, and fail LED indicators to allow you to quickly assess your network’s power level\u003cbr data-mce-fragment=\"1\"\u003e• USB port allows quick transfer of data, and up to 1,000 measurement items can be saved at once\u003cbr data-mce-fragment=\"1\"\u003e• Optional 10 minute auto-off can be activated or deactivated\u003cbr data-mce-fragment=\"1\"\u003e• Shatter-resistant sleeve protects it from accidental falls or other damage\u003cbr data-mce-fragment=\"1\"\u003e• Included software allows you to set the thresholds, transfer data, and calibrate the wavelength from your PC","brand":"Jonard","offers":[{"title":"Default Title","offer_id":40998554763369,"sku":"JT-PON-50","price":346.21,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/products\/PNG_Transparent_Background_PON-50_LR_b33315cd-1114-4d6f-ab93-71954e3d342c.png?v=1704807926"},{"product_id":"jonard-professional-multi-function-otdr-1310-1550-nm","title":"Jonard Professional Multi-Function OTDR, 1310\/1550 nm","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eJonard Professional Multi-Function OTDR, 1310\/1550 nm\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJonard Tools’ Professional Multi-Function OTDR is the perfect all-in-one handheld device for evaluating FTTx and access network construction and maintenance, identifying fibre breakpoints, measuring cable length, and calculating relative optical power losses. This OTDR also features the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes 5 different functions for testing: 1310\/1550 nm OTDR module, 1310\/1550 nm Light Source module, Power Meter module, Visual Fault Locator module, and Help module\u003c\/li\u003e\n\u003cli\u003eLarge, bright 7” colour LCD touch screen makes it quick and easy to evaluate data\u003c\/li\u003e\n\u003cli\u003eMore accurate testing with a 32\/30 Dynamic Range\u003c\/li\u003e\n\u003cli\u003eFeatures Dual Wavelength Testing (see both 1310 \u0026amp; 1550 wavelengths simultaneously)\u003c\/li\u003e\n\u003cli\u003eBuilt-in Event Map shows faults with graphical images for simplified troubleshooting\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0615\/8463\/8152\/files\/image002_480x480.png?v=1709203933\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHandy stylus to keep LCD screen fingerprint free\u003c\/li\u003e\n\u003cli\u003eRubberized hard plastic case is shock-proof and drop-proof for maximum durability\u003c\/li\u003e\n\u003cli\u003e200 MB Internal storage stores up to 4,800 entries, with MicroSD\/TF card slot for additional memory\u003c\/li\u003e\n\u003cli\u003eBuilt-in rechargeable lithium-ion battery provides power on-the-go\u003c\/li\u003e\n\u003cli\u003eOn-board Wi-Fi connectivity for data transfers or live viewing of data (for Android devices)\u003c\/li\u003e\n\u003cli\u003eCan be charged or connected to a computer for data transfer via included micro-USB cable\u003c\/li\u003e\n\u003cli\u003eIncludes FC\/APC \u0026amp; SC\/APC OTDR adapters, LC\/UPC adapter for OPM, downloadable software (also featured in the download section of this product page), power adapter, calibration certificate and instruction manual\u003c\/li\u003e\n\u003cli\u003eConvenient unit kickstand\u003c\/li\u003e\n\u003cli\u003eProtective carrying case with adjustable strap\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"627\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"459\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003eWavelengths\u003c\/td\u003e\n\u003ctd width=\"459\"\u003e1310±20nm, 1550±20nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003eFibre Type\u003c\/td\u003e\n\u003ctd width=\"459\"\u003eG.652 SingleMode Fibre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003eDynamic Range\u003c\/td\u003e\n\u003ctd width=\"459\"\u003e32 dB\/30 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003eEvent Blind Zone\u003c\/td\u003e\n\u003ctd width=\"459\"\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003eATT Blind Zone\u003c\/td\u003e\n\u003ctd width=\"459\"\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003eTest Range\u003c\/td\u003e\n\u003ctd width=\"459\"\u003e500m-80km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003ePulse Width\u003c\/td\u003e\n\u003ctd width=\"459\"\u003e3ns-10us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003eRange Accuracy\u003c\/td\u003e\n\u003ctd width=\"459\"\u003e±（0.75 m + Sampling Interval + 0.0025％× Test Distance）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003eLoss Accuracy\u003c\/td\u003e\n\u003ctd width=\"459\"\u003e± 0.02 dB\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003e# of Sampling Points\u003c\/td\u003e\n\u003ctd width=\"459\"\u003e256k\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003eSampling Resolution\u003c\/td\u003e\n\u003ctd width=\"459\"\u003e0.5m-32 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003eReflection Accuracy\u003c\/td\u003e\n\u003ctd width=\"459\"\u003e± 2 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003eData Storage\u003c\/td\u003e\n\u003ctd width=\"459\"\u003eInternal: 200 MB; External: MicroSD Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003eLaser Safety Level\u003c\/td\u003e\n\u003ctd width=\"459\"\u003eClass II level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003eFile Format\u003c\/td\u003e\n\u003ctd width=\"459\"\u003eSOR Standard File Format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003eIncluded Connectors for OTDR\u003c\/td\u003e\n\u003ctd width=\"459\"\u003eFC, SC (APC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003eDimensions\u003c\/td\u003e\n\u003ctd width=\"459\"\u003e33.02 cm x 11.43 cm x 24.13 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003eWeight\u003c\/td\u003e\n\u003ctd width=\"459\"\u003e2.87Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"168\"\u003eUPC #\u003c\/td\u003e\n\u003ctd width=\"459\"\u003e\u003cspan\u003e810053352113\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Jonard","offers":[{"title":"Default Title","offer_id":41498932084841,"sku":"OTDR-1500","price":3372.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1362\/8711\/files\/PNG_Transparent_Background_-_OTDR-1500_1_8e8ca5fe-08cf-4cc9-b068-bff71070bcf4.png?v=1715612411"}],"url":"https:\/\/networx-direct.myshopify.com\/collections\/fibre-testers.oembed","provider":"networktesters.co.uk","version":"1.0","type":"link"}